O p t i o n s a n d Te c h n i c a l D a t a

V F D P A C K A G E S

Harrington’s standard variable frequency drive packages for ER hoists include:

VFD installed in a NEMA 12/13 electrical enclosure

VFD programmed & tested to customer’s specs for speed(s) and/or acceleration

Branch circuit fuses to protect the VFD and the hoist motor

Mounting bracket for VFD enclosure

Wiring and hardware

L O A D L I M I T E R

Reduces the potential for making hazardous, over-capacity lifts. The load limiter is preset at 115% of rated capacity and protects the hoist mechanism from damage due to overloading. Overloading the hoist electrically activates the load limiter, making the hoist inoperable (load can still be lowered at any time).

C O R R O S I O N - R E S I S T A N T C H A I N S

These special premium chains give the advantage of increased resistance to corrosion. Ideal for job sites affected by rain, saltwater, steam and chemicals.

Both NP (Nickel Plated) and

ND (Nickel Diffused) load chains offer superior resistance to corrosive conditions.

46

Corrosion Resistance Test Results for NP and ND Chains

 

 

 

 

Concentration

Resistance to

 

 

Substance

%

Corrosion

 

 

 

 

 

 

 

 

 

 

Sulfuric Acid

10

Some

 

 

 

 

 

 

 

 

Inorganic

 

Nitric Acid

10

Some

 

 

 

 

 

 

 

Hydrochloric Acid

10

Some

 

Acids

 

 

 

 

 

 

 

 

 

 

Phosphoric Acid

10

Slight

 

 

 

 

 

 

 

 

 

 

Boric Acid

5

Slight

 

 

 

 

 

 

 

 

Organic

 

Acetic Acid

10

Slight

 

 

Acids

 

Tartaric Acid

10

No

 

 

 

 

 

 

 

 

 

 

 

Alkalis

 

Caustic Soda

10

No

 

 

 

 

 

 

 

 

Ammonia Hydroxide

10

Slight

 

 

 

 

 

 

 

 

 

 

 

 

Air-Indoor/Outdoor

No

 

 

 

 

 

 

 

 

Others

 

Seawater

Slight

 

 

 

 

 

 

 

 

 

 

Seasonings

No

 

 

 

 

 

 

 

Results listed in this table are for chemicals in a pure state. The degree of corrosion resistance may differ from this table with the presence of other chemicals, different concentrations, mixed substances or damage to the nickel surface layer.

U N I V E R S A L L A T C H K I T S

Generic design to fit most hooks. Available in standard steel or stainless steel. Neck and throat dimensions can be combined for proper fit. (Example, neck size E with throat size L.) Neck measurement must be diameter— not circumference. Latch kit brochures available upon request. Contact Customer Service for dimensions not shown.

Latch Kit

Neck Diameter

Throat Opening

 

Product

N

T

 

Code

(in)

(in)

 

A

916 to 58

1116 to 118

 

B

34 to 1316

114

 

C

78 to 1

138 to 112

 

D

118 to 114

134 to 178

 

E

138 to 112

2116

 

F

158 to 11116

214

 

G

134 to 11316

212

 

H

178 to 2

3

 

J

2116 to 218

338

Figure 1—Latch Kits

K

2316 to 214

312

 

L

2516 to 238

334

 

M

2716 to 234

4

 

O

3 to 314

412

 

Page 36
Image 36