39

E. Combustible Mantel

See Figure 11.11.
A combustible mantel may be positioned no
lower than 12 in. (305 mm) above the top of the
replace opening.
A combustible mantel may have a maximum
depth of 12 in. (305 mm).
Combustible trim and materials cannot be placed
within 6 in. (152 mm) of the replace opening
(top or sides).
Combustible materials projecting more than
1-1/2 in. (38 mm) shall not be placed within
12 in. (305 mm) from the top of the replace
opening.
• Combustible trim must not cover the metal
surfaces of the replace.
Mantel clearance is in accordance with Section
7-3.3.3 of ANSI/NFPA211.
6 ft (1829 mm
MINIMUM
base of fireplace
to ceiling
Combustible Wall
2 x 4 stud wall
Standoffs
Measured from top of fireplace opening
12 in./305 mm MAXIMUM
12 in.305 mm MINIMUM
Combustible Decorative Facing
Noncombustible
Decorative Facing
Seal joint with
noncombustible
sealant
Figure 11.11 Clearances to Mantels or other Combustibles above Fireplace

F. Sidewalls/Surrounds

Adjacent combustible sidewalls must be located
a minimum of 12 in. (305 mm) from the replace
opening.
Combustible or noncombustible mantel legs,
surrounds and stub walls may be constructed
per Figure 11.12.
BA

12 in.

[305 mm]

9 3/4 in.

[248 mm]

12 in.

[305 mm]

10 3/4 in.

[273 mm]

FLUSH
FRONT

4 in.

[102 mm]

BRICK
FRONT
50° angle
39° angle

Grid represents 1 in. scale

Figure 11.12 Mantel Leg or Wall Projections (acceptable on both sides of opening)
Model #
A
Fireplace Opening
B
Outside Dimensions
A36 in. 36 42
mm 914 1067
A42 in. 42 48
mm 1067 1219
Heatilator • A36C & A42C • 28396 • Rev AG • 11/08