Septemer 1, 2008 7014-083E Page 9
CB1200-I Pellet Insert

A

BC

D

D. Minimum Opening for Masonry and Zero Clearance Fireplaces for Built-In Using Rear Shroud
SIDE WALL
MANTEL
D
C
E
A
B
FaceTrim
Inches Millimeters
A Louvers to combustible
side wall
6 153
B Insert top to mantel 12 305
C Top to Face Trim 3 76
D Hearth Extension - Front 6 153
E Hearth Extension - Sides 8 203
Inches Millimeters
A Rear Width 22 558
B Depth 15-1/2 393
C*Height - Top Vent 25-1/2 647
Height - Rear Vent 22-1/2 571
D Front Width 29-1/4 743
Figure 9.1
Figure 9.2
C. Minimum Clearances To Combustibles for Masonry and Zero Clearance Fireplaces
*The size of your floor protector choice must be
added to this dimension. If using Quadra-Fire floor
protector, Part 811-0730, allow 1-1/2” (38mm).
NOTE: A Quadra-Fire floor protector (Part 811-0730) is
available through your dealer to be used as a floor protector
for the section under the insert body only. Floor protection
to front and sides of insert unit must be supplied in addition
to this part.