22 Heat-N-Glo Lifestyle Collection • Dakota 42/Dakota 42H • 4036-905 Rev I • 10/05
Although the frequency of appliance servicing and maintenance will depend on use and the type of installation, a qualifi ed
service technician should perform an appliance check-up at the beginning of each heating season.
Fire Risk
Explosion Risk
Inspect external vent cap regularly.
Ensure no debris blocks cap.
• Combustible materials blocking cap may
ignite.
• Restricted air flow affects burner
operation.
WARNING
Annual inspection by qualified technician
recommended.
Check:
Condition of doors, surrounds and fronts.
Condition of glass, glass assembly and glass
seal.
Obstructions of combustion and ventilation
air.
Condition of logs.
• Condition of rebox.
Burner ignition and operation.
Burner air shutter adjustment.
• Gas connections and ttings.
Obstructions of termination cap.
Clean:
• Glass.
• Air passageways, grilles, control
compartment.
• Burner, burner ports.
Risk of:
Fire
Delayed ignition or explosion
Exposure to combustion fumes
• Odors
WARNING
Handle glass assembly with care.
Note: Clean glass after initial 3-4 hours
operation. Longer operation without
cleaning glass may cause a permanent
white fi lm on glass.
When cleaning glass door:
• Avoid striking, scratching or slamming
doors.
Do NOT use abrasive cleaners.
Use a hard water deposit glass cleaner on
white fi lm.
Do NOT clean glass when it is hot.
• Turn off appliance after 3-4 hours of
operation and ALLOW TO COOL.
Remove and clean glass assembly.
• Replace glass assembly and operate
appliance for an additional 12 hours.
Refer to maintenance instructions.
CAUTION
12
Maintaining and Servicing the Appliance
Risk of injury or property damage
Before servicing:
• Turn off gas.
Turn off electricity to appliance.
Disable remote control, if one is present.
Ensure appliance is completely cooled.
After Servicing:
Replace any screen or barrier that was removed.
• Reseal and reinstall any venting removed for
servicing.
WARNING