33
Slanted Roofs
Flat Roofs
Chimney must
extend 3 ft (.9 m)
above the roof
Chimney must extend 2 ft (.6 m)
above any portion of the roof or
adjacent structures within
10 ft (3 m) of the chimney
Chimney must
extend 3 ft (.9 m)
above the roof
Chimney must extend 2 ft (.6 m)
above any portion of the roof or
adjacent structures within
10 ft (3 m) of the chimney
Multiple Chimney Locations
AB
6in.(minimum)upto20in.
152mm/508 mm
18in. minimum
457mm
20in. and over 0in. minimum
Gas, Wood or Fuel Oil
Termination Cap
Wood
Minimum
(See
illustration
above)
B
Gas
Termination
Cap **
A *
Perpendicular Wall
*Ifusingdecorativecapcover(s),thisdistancemayneedtobe
increased.Refer to the installation instructions supplied with the
decorativecap cover.
** Ina staggered installation with both gas and wood terminations, t he
woodtermination cap must be higher than the gas term ination cap.
Figure 8.10 Multiple Chimney Locations
J. Chimney Termination Requirements• Install a cap approved and listed for this fi replace system.
• Locate cap where it will not become plugged by snow or other materials.
• Locate cap away from trees or other structures.
• The bottom of the termination cap must be at least 3 ft (.91 m) above the roof AND at least 2 ft (.61 m) above any portion
of roof within 10 ft (3.05 m) as shown in Figure 8.10.
• The distance required between caps is shown in Figure 8.10.
Heat & Glo • EXCLAIM-50 • 4013-041 • Rev U • 11/08