E. Install Attic Insulation Shield

WARNING! Risk of Fire! You MUST install an attic in- sulation shield when there is any possibility of insulation or other combustible material coming into contact with the chimney.

DO NOT pack insulation between the chimney and the attic insulation shield.

Failure to keep insulation and other materials away from chimney pipe could cause fire.

DO NOT offset chimney inside insulation shield.

Installation of a ceiling firestop is required

Refer to Figures 8.6 - 8.8.

Roll the shield around the chimney (if chimney is already installed) until you have a 3 in. (76 mm) overlap and the three holes on each side match up (large holes on top).

Insert three screws into the matching holes to form a tube.

Bend three tabs on the bottom of the tube inward to 90° to maintain chimney air space as shown in Figure 8.6.

Rest the insulation shield on the ceiling firestop below.

Bend the three short tabs at the top of the shield inward to 90° to maintain the 2 in. (51 mm) air space from the chimney.

Bend the remaining top tabs to just meet the pipe.

If you wish to make a custom shield or barrier, follow these guidelines:

Metal is preferred, although any material stiff enough to hold back the insulation can be used.

WARNING! Risk of Fire! Use of cardboard or other materials that can deflect under humidity or other envi- ronmental conditions is not recommended.

The shield or barrier must be tall enough to extend above the insulation and prevent blown-in insulation from spilling into the cavity.

The shield should be affixed to building structure.

Maintain specified air spaces around chimney.

Check instructions and local codes for further details.

 

 

 

 

Bend remaining tabs

 

 

 

 

to rest against pipe to

Bend

 

inward

prevent insulation

90°

 

from falling in.

 

 

 

 

 

Insert three

 

 

 

 

screws

3 in. (76 mm) overlap

Figure 8.6 Prepare Attic Insulation Shield

 

 

Tabs bent in to

 

Pipe

rest against pipe

 

 

 

 

Attic Insulation Shield

 

 

17 in. (432 mm)

 

6 Tabs bent

diameter

 

in 90°

Ceiling Firestop

 

 

Insulation

Pipe

Insulation

13 in.

 

 

(330 mm)

 

 

Figure 8.7 Install Attic Insulation Shield Above the Ceiling

 

 

Tabs bent in to

 

 

rest against pipe

 

Pipe

 

 

 

Attic Insulation Shield

 

 

17 in. (432 mm)

 

 

diameter

 

6 Tabs bent

 

 

in 90°

 

Insulation

 

Insulation

13 in.

Pipe

Ceiling Firestop

(330 mm)

 

 

Figure 8.8 Install Attic Insulation Shield Below the Ceiling

Heat & Glo • RUTHERFORD-424059-309 Rev G • 11/08

29

Page 29
Image 29
Hearth and Home Technologies RUTHERFORD-42 owner manual Install Attic Insulation Shield, Prepare Attic Insulation Shield

RUTHERFORD-42 specifications

Hearth and Home Technologies presents the RUTHERFORD-42, an exceptional gas fireplace that combines sophisticated design with advanced functionality. This model signifies the perfect blend of aesthetics and performance, making it a favored choice for homeowners seeking to enhance their living spaces with the warmth and comfort of a fireplace.

One of the primary features of the RUTHERFORD-42 is its impressive viewing area, measuring 42 inches wide. This expansive glassfront design offers a stunning visual display of the flames, creating a cozy ambiance that enhances any room. The fireplace is framed with a stylish surround that can be customized to match various interior styles, adding a touch of elegance to contemporary and traditional homes alike.

Equipped with advanced technology, the RUTHERFORD-42 ensures efficient heat output while maintaining ease of use. The fireplace features an electronic ignition system that provides reliability and convenience with a simple push-button start. Additionally, it incorporates a thermostat remote control, allowing users to easily regulate the temperature from anywhere in the room. This functionality not only enhances user comfort but also improves energy efficiency.

The unit is designed with a powerful yet quiet fan that circulates warm air throughout the space, ensuring even heat distribution. This makes the RUTHERFORD-42 an excellent option for supplemental heating in larger rooms, providing both style and warmth during colder months.

Safety is a paramount concern in all Hearth and Home Technologies products, and the RUTHERFORD-42 is no exception. It includes safety screens that protect against accidental contact with the flames, ensuring peace of mind while enjoying the fire’s warmth. Furthermore, it complies with stringent safety standards, making it a reliable choice for families.

In terms of aesthetics, the RUTHERFORD-42 offers various media options, including glass, ceramic logs, and stone, allowing homeowners to personalize the fire's appearance to align with their home’s décor. The fireplace is also available in different finishes, giving users the flexibility to create a focal point that perfectly complements their interior design.

Overall, the Hearth and Home Technologies RUTHERFORD-42 is a standout model that combines cutting-edge technology, safety features, and design flexibility, making it an excellent choice for anyone looking to add a stylish and functional gas fireplace to their home.