Heat & Glo LifeStyle 7000XLS, 6000XLSB manual Venting with ONE 1 90 Elbow

Models: 6000XLSB 7000XLS

1 25
Download 25 pages 62.08 Kb
Page 10
Image 10

VENTING WITH ONE (1) 90° ELBOW

V

 

H

1' MIN. (305mm)

2'

MAX. (610mm)

2' MIN. (610mm)

4'

MAX. (1.22m)

3' MIN. (914mm)

6'

MAX. (1.86m)

4' MIN. (1.22m)

8'

MAX. (2.4m)

V+H=40' MAX. (12.4m)

H = 8' MAX. (2.4m)

 

 

 

NOTE: On vertical venting configurations where the vertical component is over 10 feet, you may want to install the vertical baffle included in the manual bag assembly to improve flame appearance.

Figure 7. Venting with One 90° Elbow

VENTING WITH TWO (2)

90° ELBOWS

V

H

H + H1

1´ MIN. (305 mm)

2´ MAX. (610 mm)

6´ MAX. (1.82m)

2´ MIN. (610 mm)

4´ MAX. (1.22 m)

12´ MAX. (3.65m)

3´ MIN. (914 mm)

6´ MAX. (1.86 m)

18´ MAX. (5.48m)

4´ MIN. (1.22 m)

8´ MAX. (2.48 m)

24´ MAX. (7.31m)

V+H+H1 = 40´ MAX. (12.4 m) H = 8´ MAX. (2.48 m)

H+H1 = 24´ MAX. (7.31m)

 

 

 

Figure 8. Venting with Two 90° Elbows