3Installing the Fireplace
Step 1. | Locating the Fireplace | Step 2. Framing the Fireplace |
The diagram below shows space and clearance require- ments for locating a fireplace within a room.
TOP VIEW
| GLASS | 36" |
|
| |
36" | GLASS | 1" |
Figure 2. Fireplace Dimensions, Locations, and Space Requirements
Clearance Requirements
The top and ends of the fireplace are defined by
Minimum Clearances from the Fireplace to
Combustible Materials | Inches | mm |
| ||
Glass Front | 36 | 914 |
Floor | 0 | 0 |
Metal Ends | 1/2 | 13 |
Top | 3 | 76 |
Ceiling* | 31 | 787 |
*The clearance to the ceiling is measured from the top of the unit, excluding the
Minimum Clearances from the
| Inches | mm |
Vertical Sections | 1 | 25 |
Horizontal Sections |
|
|
Top | 1 | 25 |
Bottom | 1 | 25 |
Sides | 1 | 25 |
At Wall Firestops |
|
|
Top | 1 | 25 |
Bottom | 1 | 25 |
Sides | 1 | 25 |
Fireplace framing can be built before or after the fireplace is set in place. Framing should be positioned to accommo- date wall coverings and fireplace facing material. The dia- gram below shows framing reference dimensions.
CAUTION: MEASURE FIREPLACE DIMENSIONS AND VERIFY FRAMING METHODS AND WALL COVERING DETAILS BEFORE FRAMING.
NOTE: If an optional blower (Model
Framing should be constructed of 2 X 4 lumber or heavier.
12"
B
12"
C
A
Model | A | B | C |
| 39 5/8 | 38 3/4 | 21 1/16 |
NOTE: DIMENSIONS SHOWN IN INCHES
Figure 3. Framing Dimensions
9