Heat Controller SMA 18 Installation Precaution, SMA/SMH 18/24, Installation Instructions

Models: SMA 18

1 14
Download 14 pages 16.53 Kb
Page 2
Image 2
SMA/SMH 18/24

SMA/SMH 18/24

INSTALLATION INSTRUCTIONS

Heat Controller, Inc.

Installation Manual for Single Zone Ductless Mini-Split

For correct installation, read this manual before starting the installation. Please save this manual in a safe place.

Only trained and qualified service personnel should install, repair or service air conditioning equipment. Users should not install the air conditioner by themselves.

Pictures in this manual may be slightly different from the air conditioner you purchased. These pictures are only representations.

INSTALLATION PRECAUTION

Installation in the following places is not recommended.

Near equipment which contains or uses oil.

Coastal locations where exposure to high winds and high concentrations of salt in the air may damage the air conditioner.

A location with exposure to sulfide gas such as hot-spring resort.

Places where there are high frequency machines such as wireless equipment, welding machines, or in a medical facility. The unit uses a remote controller and may cause electrical interference with nearby wire- less equipment.

A location with abnormal environmental conditions such as locations where the unit is exposed to exces- sively high or low ambient temperatures, exposure to adverse weather, corrosive fumes, dust laden or moisture-laden atmospheres and hazardous locations.

A location where there are combustible gases or volatile matter.

Recommended Areas of Installation

Indoor Unit

A place where there are no obstacles or blockages, near the inlet or outlet airflow areas of the unit.

A place which can bear the weight of the indoor unit.

A place which provides adequate clearance around the indoor unit as required.

A place 3.3ft or more away from TV or radio equipment to ensure there is no electronic/wireless interference.

A place which is far away from heat or steam sources and flammable gas.

Install the indoor unit on the wall where the height from the floor is more than 7.5 feet.

Outdoor Unit

A place which is convenient for installation and not exposed to a high winds or air with high concentra- tions of salt content.

A place which can bear the weight of the outdoor unit.

A place where the outdoor unit can be installed in a horizontal level position.

A place where the operation noise and discharge air will not disturb others.

A place free from leakage of combustible gases.

Where an allowable head level for the connective piping is less than 16 feet and length of the connective piping is less than 33 feet.

A place which provides recommended clearance around the outdoor unit.

Note:

1.The appliance should not be installed in the laundry room.

2.All the connections must be in accordance with local and national electric codes.

3.For power details of the air conditioner, refer to the rating plate of the product.