7
Air Handler Component Unit Size
03 06 08 10 12 14 18 20 26 34 41 50 65 75
290 430 500 550 650 790 816 836 968 1188 1386
946 1177 1518 1782 2700 3300 4496
318 450 553 600 732 988 1033 1067 1221 1474 1672
1177 1430 1793 2057 2850 3480 4690
296 387 482 535 615 860 1004 1111 1254 1628 1881
170 280 312 360 450 510 564 605 693 902 1078
715 891 1221 1474 2600 3200 3359
162 266 296 342 428 485 536 575 658 857 1024
679 846 1160 1400 2470 3040 3191
60 73 83 95 99 104 106 108 115 160 185 255 315 384
66 79 89 101 106 114 126 135 165 240 275 390 460 560
75 88 98 110 119 124 126 127 130 185 210 298 351 428
149 168 187 206 215 224 230 234 244 260 290 360 440 535
155 176 196 216 225 234 240 244 254 365 450 520 650 790
82 95 112 133 133 153 175 180 194 235 248 269 330 359
103 121 143 170 170 196 225 224 246 296 318 345 425 463
127 150 173 201 201 230 264 274 299 358 380 412 516 552
174 195 216 224 236 247 254 260 300 430 550 680 800 975
323 363 403 430 451 471 484 494 544 690 840 1040 1240 1510
52 68 79 100 115 138 148 155 180 260 350 420 520 634
57 75 87 110 128 155 166 175 200 286 385 462 650 793
129 164 204 208 223 306 280 261 310 331 362 515 640 1305
157 184 257 258 305 504 497 492 563 617 648 665 820 1499
223 356 454 550 670 774 954 1104 1434 1760 2118 2481 3143 3599
36 56 70 80 94 106 110 112 144 195 239 339 406 538
50 80 101 120 143 164 169 173 228 318 396 562 673 891
64 106 134 161 195 223 231 236 314 444 557 737 936 1168
78 132 168 202 246 282 292 299 398 569 718 913 1199 1445
109 187 240 290 353 408 422 432 578 830 1052 1278 1677 2017
141 242 311 379 461 534 552 565 760 1092 1385 1638 2154 2589
172 297 383 467 569 659 682 699 942 1355 1718 2194 2893 3478
Section
Air Handler Motor and Drive Motor Horsepower, 1800 RPM
1 1.5-2 3 5 7.5 10 15 20 25 30 40 50 60 75
55 65 86 105 172 193 253 286 348 400 529 600 720 828
56 71 88 104 178 194 275 336 411 461 624 670
67 74 114 127 209 216 341 384 396 427 621 623
71 97 115 160 291 267 368 356 366
143 145 182 184 213 215 254 256 284 286 324 326 364 365
Weight in pounds
Motor Open Single Speed Motor
and Totally Enclosed Fan Cooled (TEFC)
Drive High Efficiency Open Single Speed
Weight Open 2 Speed, 2 Winding
T – Frame Size
(Coil weight include the weight of water when filled)
TA = Throw away type filters For 1/2” Tube (Type A): Multiply Type 5 Coil Weight by- 0.800
AF = Airfoil Fan For Small Coil: Multiply Large Coil Weight by- 0.823
FC = Forward Curved Fan For 14 FPI: Multiply 10 FPI Coil weight by- 1.121
For 12 FPI: Multiply 10 FPI Coil weight by- 1.065
For 8 FPI: Multiply 10 FPI Coil weight by- 0.935
For 6 FPI: Multiply 10 FPI Coil weight by- 0.915
To Estimate Weights for Other Coils
Central Station Air Handler, Shipment of Assemblies - Basic Unit
Horizontal Style Units, fan, coil, flat filter section Vertical Style Units, fan, coil, flat filter section
S, L, FO,
HD Sizes
03 – 18
S, L, FO,
HD Sizes
20 – 75
FS
CS
FF
FS
CS
FF
These diagram show
typical shipments.
Some set-ups may
vary with certain units.
Consult the factory if
you require a specific
assembly shipped in a
special way.
We ship high capacity
and high efficiency filter
sections, economizers,
dampers, and electric
heat sections separately.
V Sizes
03 – 18
V Sizes
20 – 41
CS
FF
FS
CS
FF
FS
Large Other Filter Fan and Coil Coils Accessories Section Section
Model ID Description Fan
S Short FC
S Short AF
L Long FC
L Long AF
V Vertical FC
HD Heating Duty FC
HD Heating Duty AF
FO Fan Only FC
FO Fan Only AF
Flat -TA & Pleated 2”
Flat -Permanent 2”
Flat -Pleated 4”
High Capacity -TA & Pleated
High Capacity -Permanent
High Efficiency- 21” Section
High Efficiency- 28” Section
High Efficiency- 44” Section
Economizer
Combination Filter & Economizer
Internal Face and Bypass
External Face and Bypass
S Auxiliary Coil Module
L Auxiliary Coil Module
Electric Heater
1 Row
2 Row
3 Row
4 Row
6 Row
8 Row
10 Row
5/8” Tube
(Type 5)
10 FPI