TESTING
❒Turn on the circuit breaker and light switch.
Note: Sensor has a 1 1/2 minute warm up pe- riod before it will detect motion.When first turned on wait 1 1/2 minutes.
❒Set SENSITIVITY to mid position and
TEST 1 5 10 MIN | LO - M - HI |
SENSITIVITY |
Avoid aiming the control at:
•Pools of water or objects that change temperature rapidly, such as heating vents and air conditioners. These heat sources could cause false triggering.
•Areas where pets or traffic may trigger the control.
•
The detector is less sensitive to motion di- rectly towards it and more sensitive to across motion.
MotionMotion
Sensor
Least Sensitive | Most Sensitive |
❒Walk through the coverage area noting where you are when the lights turn on. Move the sensor head left or right to change the coverage area.
Note: Grasp the sensor only as shown and turn the entire sensor. Any other method may damage the sensor. Do not force it past the stops.
150°
6 ft.
(1.8 m)
30ft.
(9.1m)
Maximum Range | Maximum |
| Coverage Angle |
240° | Sensor Aiming |
| |
| Adjustment Angle |
❒SettheSENSITIVITYasneeded.Toomuch sensitivity may increase false triggering.
❒Set the amount of TIME you want the light to stay on after motion is detected (1, 5, or 10 minutes).