To Deactivate the Flash Alert

To Deactivate the Flash Alert

TEST AND ADJUSTMENT WARNING: Turn power off at circuit breaker or fuse.

Remove the light fixture if necessary.

Locate the (Blue) wire loop coming from the sensor inside the canopy.

Cut the (Blue) wire loop.

Securely attach wire nuts (supplied) to each of the cut ends of the (Blue) wire. DO NOT connect the wires together.

Mount light control to wall or eave.

TEST AND ADJUSTMENT

Turn on the circuit breaker and light switch.

NOTE: Sensor has a 1 1/2 minute warm up period before it will detect motion. When first turned on, wait 1 1/2 minutes.

Turn the SENSITIVITY (SENS) control to the mid posi- tion and the ON-TIME control to the TEST position.

ON-TIME

 

SENS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10 5 1 TEST

MIN MAX

Bottom of Sensor

Flash Alert - Deactivated

(Blue)

Mount the Light Control

Align the light control cover plate and the junction box holes. Secure with the mounting screws.

If not installed on a weatherproof box or if an adaptor plate (not included) was used, caulk the wall plate and mounting surface with silicone.

Avoid water damage and electrical shock - keep lamp holders below horizontal.

Lock nuts

Keep lamps at least 1" (25 mm) from the sensor.

Adjust the lamp holders by loosening the lock nuts but do not rotate the lamp holders more than 180° from the factory setting.When screwing in the flood- lamps, do not overtighten.

598-1303-01

Page 3