Heath Zenith 6106 owner manual Specifications, Completing Installation, Adjustments

Models: 6106

1 16
Download 16 pages 30.6 Kb
Page 3
Image 3
COMPLETING INSTALLATION

3.For test purposes, use a small, phillips screw- driver to turn the TIME control to the TEST (5 second) position (see Figure 4). Turn the power back on at the circuit breaker.

4.Verify the switch has power. The bottom LED will be lit.

5.Allow the sensor to stabilize (about 1 minute). The sensor is ready to detect motion.

6.Push the ON/OFF button. The lights and mo- tion sensor will turn on. The lights will remain on as long as the sensor detects motion or the ON/OFF button is pushed again. The lights will turn off 5 seconds after motion stops.

5

1 ADJUSTMENTS 10

Test 25 15

T I M E

Figure 4 - Control Panel

COMPLETING INSTALLATION

1.Replace control panel cover and attach the decorative wall plate. In installations where the Heath®/Zenith motion sensor switch is combined with other switches or outlets on an expanded box, you will need to purchase a combination wall plate. Various combination wall plates are available at home centers and electrical supply stores.

2.PushtheON/OFFbutton.Verifytheswitchturns on the lights and the top LED is on.

3.Push the ON/OFF button again and verify the lights turn off and the top LED is off.

4.Push the ON/OFF button again to turn lights and sensor on. Leave the room or stay completely still for the amount of time you selected for the lights to stay on. Verify the lights turn off at the desired time.

Note: The motion sensor requires a 2 second delay when switching off and on using the ON/OFF button.

ADJUSTMENTS

Time

There are 6 preset selections for the amount of time the lights stay on: Test (5 seconds), 1, 5, 10, 15, and 25 minutes. Use a small, phillips screw driver to adjust the TIME control (see Figure 4). Turn the TIME control until it “snaps” into the desired time position.

 

SPECIFICATIONS

Electrical Input

120V, 60 Hz.

Fluorescent* Load

30 Watts minimum, Up to 400 Watts Maximum

Motor Load

Up to 1/8 HP Maximum

Incandescent

Up to 500 Watts Maximum at 120VAC

On-Time

Selectable, approximately 5 seconds to 25 minutes

Coverage

up to 15 ft. (4.6 m) at 180°, up to 30 ft. (9.1 m) in front of the sensor

*Designed for use with standard 3 ft./30 watt and 4 ft./40 watt rapid-start fluorescent tubes.