Heath Zenith BL-2400 manual Installation, Eave Mount, Wall Mount, Wire the Light Control

Models: BL-2400

1 12
Download 12 pages 7.01 Kb
Page 2
Image 2
INSTALLATION

INSTALLATION

Wire the Light Control

For easy installation, select an existing light operated by a wall switch for replacement.

For best performance, mount the fixture about 8 feet (2.4 m) above the ground.

Drill the holes needed to mount the backplate to the junction box.

Wire the Light ControlWARNING:Turn power off at the fuse or circuit breaker.

Remove the existing light fixture.

Route the light control’s wires through the large gasket hole.

Connect the junction box wires to the light control wires. Twist together and secure with a wire connector.

Black to

White to Black

WhiteGasket

Eave Mount

Wall Mount

For under eave installation, the sensor head must be rotated as shown in the next two steps for proper operation and to avoid the risk of electrical shock.

For eave mount only:

Rotate the sensor head towards the clamp screw joint.

Control Switch

Joint Clamp Black to

Mount the Light Control

Align the light control cover plate and the junction box holes. Secure with the mounting screws.

If not installed on a weatherproof box or if an adaptor plate (not included) was used, caulk the wall plate and mounting surface with silicone.

Avoid water damage and electrical shock - keep lamp holders below horizontal.

Then rotate the sensor head clockwise 180° so the controls face down.

Lock nuts

Keep lamps at least 1" (25 mm) from the sensor.

Adjust the lamp holders by loosening the lock nuts but do not rotate the lamp holders more than 180° from the factory setting.When screwing in the flood- lamps, do not overtighten.

598-1322-01

Page 2
Image 2
Heath Zenith BL-2400 Installation, Eave Mount, Wall Mount, Wire the Light Control, Black to White to Black WhiteGasket