TEST AND ADJUSTMENT

TEST AND ADJUSTMENT

Turn on the circuit breaker and light switch.

NOTE: Sensor requires about 1 1/2 minutes to calibrate before it will detect motion. When first turned on, wait about 1 1/2 minutes.

Set the ON-TIME control to the TEST position.

ON-TIME

10 TEST

Bottom of Sensor

Avoid aiming the control at:

Loosen the clamp screw in the sensor ball joint and gently rotate the sensor to aim.

Walk through the coverage area noting where you are when the lights turn on. Move the sensor head up, down, or sideways to change the cover- age area.Keep the sensor at least 1" (25 mm) away from the lamps.

Secure the sensor head into position by tightening the clamp screw. Do not over- tighten the screw.

Set the ON-TIME control to 10 minutes.

Clamp

Ball

Joint

Aim Sensor

Down for Short

Coverage

Aim Sensor

Higher for Long

Coverage

Objects that change temperature rapidly, such as heating vents and air conditioners. These heat sources could cause false triggering.

Areas where pets or traffic may trigger the control.

Nearby large, light-colored objects reflecting light may trigger the shut-off feature. Do not point other lights at the sensor.

110°

8ft.

(2.4 m)

 

50 ft.

 

Maximum

(15.2 m)

Maximum

 

Range

 

Coverage Angle

The control is most sensitive to motion across it.

MotionMotion

 

Sensor

Least Sensitive

Most Sensitive

SPECIFICATIONS

Range

Up to 50 ft.(15.2 m);[varies with

 

surrounding temperature]

Sensing Angle. . . .

Up to 110°

Electrical Load. . . .

Up to 150 Watts Maximum

 

tungsten

Power Requirements. . 120 VAC, 60 Hz

Operating Modes. . .

TEST, AUTO and MANUAL

 

MODE

Time Delay

10 minutes

Sensitivity . . . . . . Adjustable

Replacement lamp. . . T 150W (or less) halogen 120

VAC

HeathCo LLC reserves the right to discontinue prod- ucts and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold.