TEST AND ADJUSTMENT
❒Turn on the circuit breaker and light switch.NOTE: Sensor requires about 1 1/2 minutes to calibrate before it will detect motion. When first turned on, wait about 1 1/2 minutes.
❒Set the
10 TEST
Bottom of Sensor
Avoid aiming the control at:❒Loosen the clamp screw in the sensor ball joint and gently rotate the sensor to aim.
❒Walk through the coverage area noting where you are when the lights turn on. Move the sensor head up, down, or sideways to change the cover- age area.Keep the sensor at least 1" (25 mm) away from the lamps.
❒Secure the sensor head into position by tightening the clamp screw. Do not over- tighten the screw.
❒Set the
Clamp |
Ball |
Joint |
Down for Short
Coverage
Aim Sensor
Higher for LongCoverage
•Objects that change temperature rapidly, such as heating vents and air conditioners. These heat sources could cause false triggering.
•Areas where pets or traffic may trigger the control.
•Nearby large,
110°
8ft.
(2.4 m)
| 50 ft. |
|
Maximum | (15.2 m) | Maximum |
| ||
Range |
| Coverage Angle |
The control is most sensitive to motion across it.
MotionMotion
| Sensor |
Least Sensitive | Most Sensitive |
SPECIFICATIONS
Range | Up to 50 ft.(15.2 m);[varies with |
| surrounding temperature] |
Sensing Angle. . . . | Up to 110° |
Electrical Load. . . . | Up to 150 Watts Maximum |
| tungsten |
Power Requirements. . 120 VAC, 60 Hz | |
Operating Modes. . . | TEST, AUTO and MANUAL |
| MODE |
Time Delay | 10 minutes |
Sensitivity . . . . . . Adjustable
Replacement lamp. . . T 150W (or less) halogen 120
VAC
HeathCo LLC reserves the right to discontinue prod- ucts and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold.