Wire the Light Control

WARNING: Turn power off at circuit breaker or fuse.

Remove the existing light fixture.

Install the mounting strap as shown using two screws that fit your junction box.

The plastic hanger can be used to hold the fixture while wiring. The small end of the plastic hanger can be threaded through the hole in the center of the cover plate. The small end then goes into one of the slots on the mounting strap.

Route the light control’s wires through the large gasket holes.

Twist the junction box wires and fixture wires together as shown. Secure with wire connectors.

Mounting

 

 

 

Black to

 

White to

Strap

Black

 

White

 

 

 

 

Rubber

Plug

Mounting

Bolt

Gasket

Junction box ground wire to green ground screw on fixture.

Mount the Light Control

Align the light control cover plate and cover plate gasket. Secure with the mounting bolt.

Align the three slots in the decorative shell with the bulb holder pins. Push the shell in and then twist clockwise to lock. Repeat for other shell.

Shell Slot

Push the rubber plug firmly into place.

If a wet location junction box was not used, caulk the wall plate mounting surface with silicone weather sealant.

To avoid water damage and electrical shock, keep bulb holders 30° below horizontal.

 

Keep bulbs at least

 

1" (25 mm) from the

Lock Nut

sensor. Do not allow

 

the bulbs to block

Lens

the lens.

Adjust the bulb holders by loosening the lock nuts but do not rotate the bulb holders more than 180° from the factory setting.When screwing in the floodlamps, do not overtighten.

598-1152-03

Page 3
Image 3
Heath Zenith SH-5105 manual Mounting Black to White to Strap, Junction box ground wire to green ground screw on fixture