Heath Zenith SH-5408 Test And Adjustment, Specifications, Motion, Least Sensitive, Maximum Range

Models: SH-5408

1 16
Download 16 pages 51 Kb
Page 3
Image 3
TEST AND ADJUSTMENT

TEST AND ADJUSTMENT

Turn on the circuit breaker and light switch.

The detector is most sensitive to motion across its field of view.

NOTE: Sensor has a 1 1/2 minute warm up period before it will detect motion. When first turned on, wait 1 1/2 minutes.

Motion

Motion

NOTE:Meets the ENERGY STAR® guidelines when used with 120 W Max bulbs.

 

Sensor

Least Sensitive

Most Sensitive

Turn the SENSITIVITY (SENS) control to the medium position (halfway between MIN and MAX) and the ON-TIME control to the TEST position.

SENS

ON - TIME

MIN MAX

10 5 1 TEST

Bottom of Sensor
Avoid aiming the control at:

• Objects that change temperature rapidly, such as

heating vents and air conditioners. These heat

Loosen the clamp screw in the sensor ball joint and gently rotate the sensor.

Walk through the coverage area noting where you are when the lights turn on. Move the sensor head up, down, or sideways to change the cover- age area.Keep the sensor at least 1" (2.5 cm) away from the lamps.

Adjust the SENSITIVITY as needed . Too much sensitivity may increase false triggering.

Secure the sensor head by tightening the clamp screw. Do not overtighten the screw.

Clamp

❒Turn on the circuit breaker and light switch. Screw

Motion Ball

Joint

Aim Sensor

Down for Short

Coverage

Aim Sensor

Higher for Long

Coverage

 

sources could cause false triggering.

Areas where pets or traffic may trigger the control.

Nearby large, light-colored objects reflecting light

 

may trigger the shut-off feature. Do not point other

 

lights at the sensor.

Set the amount of TIME you want the lights to stay on after motion is detected (1, 5, or 10 minutes).

Warning - Risk of fire. Do not aim the lamps at a combustible surface within 3 ft. (1 m).

8 ft.

110°

 

(2.4 m)

 

60 ft.

 

(18.3 m)

 

Maximum Range

Maximum

 

Coverage Angle

SPECIFICATIONS

Range . . . . . . . Up to 60 ft. (18.3 m) [varies with surrounding temperature].

Sensing Angle. . . . Up to 110°

Electrical Load. . . . Up to 300 Watt Maximum In- candescent [Up to 150 Watt maximum each lamp holder.]

Power Requirements. 120 VAC, 60 Hz

Operating Modes. . . TEST, AUTO and MANUAL

MODE

Time Delay . . . . . 1, 5, 10 minutes Range . . . . . . . Adjustable

HeathCo LLC reserves the right to discontinue prod- ucts and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold.

598-1156-03