TEST AND ADJUSTMENT
Clamp
Screw
Ball
Joint
Aim Sensor
Down for Short
Coverage
Aim Sensor
Higher for Long
Coverage

TEST AND ADJUSTMENT

Turn on the circuit breaker and light switch.

NOTE: Sensor has a 1 1/2 minute warm up period before it will detect motion. When first turned on, wait 1 1/2 minutes.

Turn the RANGE control to the mid position and the ON-TIME control to the TEST position.

ON-TIMERANGE

10 5 1 TEST

MIN MAX

Bottom of Sensor

Avoid aiming the control at:

Objects that change temperature rapidly, such as heating vents and air conditioners. These heat sources could cause false triggering.

Areas where pets or traffic may trigger the control.

Nearby large, light-colored objects reflecting light may trigger the shut-off feature. Do not point other lights at the sensor.

8 ft.

150°

 

(2.4 m)

 

70 ft.

 

(21 m)

 

Maximum Range

Maximum

 

Coverage Angle

The detector is most sensitive to motion across its field of view.

Loosen the clamp screw in the sensor ball joint and gently rotate the sensor.

Walk through the coverage area noting where you are when the lights turn on (also, the LED will flash several times when motion is detected).Move the sensor head up, down, or sideways to change the cover- age area. Keep the sensor at least 1" (2.5 cm) away from the lamps.

Adjust the RANGE as needed. RANGE set too high may

increase false triggering.

Secure the sensor head by tightening the clamp screw.

Do not overtighten the screw.

Set the amount of TIME you want the lights to stay on after motion is detected (1, 5, or 10 minutes).

Warning - Risk of fire. Do not aim the lamps at a combustible surface within 3 ft. (1 m).

SPECIFICATIONS

Range . . . . . . . Up to 70 ft. (21 m) [varies with surrounding temperature].

Sensing Angle. . . . Up to 150°

Electrical Load. . . . Up to 300 Watt Maximum In- candescent [Up to 150 Watt maximum each lamp holder.]

Power Requirements. 120 VAC, 60 Hz

Operating Modes. . . TEST, AUTO and MANUAL

MODE

Time Delay . . . . . 1, 5, 10 minutes Range . . . . . . . Adjustable