Heath Zenith SL-6105 manual Installing Sensor

Models: SL-6105

1 12
Download 12 pages 36.42 Kb
Page 2
Image 2
Installing Sensor

Manual background WARNING: Turn power off at the circuit breaker before wiring.

Installing Sensor

Removing Control Panel Cover

1.Remove the decorative cover plate (secured by two small screws).

2.Press in with screwdriver as shown in Figure 2. Swing control panel cover out to remove.

ON

OFF

AUTO

 

Control Panel

Cover

Figure 2 - Removing Control Panel Cover

Typical Installation

1.Remove existing wall switch from junction box.

2.Connect electrical leads of sensor as shown in Figure 3. Before installing sensor into junction box, make sure there is no wire exposed at each connection.

3.Mount sensor into junction box using two large mounting screws provided.

4.For test purposes, use a small screwdriver to turn the TIME control fully counterclockwise and the LIGHT control fully clockwise. Turn the power back on at the circuit breaker.

5.Set mode selection switch to the AUTO posi- tion. When unit stabilizes (about 1 minute), the sensor is ready to detect motion. If sensor detects motion, the lights will turn on. The lights will turn off 5 seconds after motion is no longer detected.

Control

Panel

5 10

+

 

To Lighting Load

Black

Neutral

 

Return

 

Lighting Load

 

Green ground wire to

 

junction box screw or

1Manual backgroundManual background15

TestManual backgroundManual background20

T I M E L I G H T

Mode

Selection

Switch

 

grounding wire.

Black

Line

 

“Hot”

Figure 3 - Connecting Electrical Leads of Sensor