21
5 Measuring
5.4 Storing a Reference
In order to monitor dispensed quantities, reference-dispensing cycles have to be made.
Only for the Automatic Controller 97103: Choose the dispensing channel in which the
dispensing is required to be monitored.
To get the reference mode first press
the button , hold it and than press
the button .
In the display the name of the dispensing
channel changes from A (B) to
Reference.
Now reference-dispensing can be made.
Start dispensing and inspect the quality. If o. k. store it with button . .
In the display the name of the dispensing channel changes from R to A (B) and the
dispensing is stored as a reference. After storing, the controller switches to the normal
dispensing mode.
It is possible to store up to 10 different reference-dispensing cycles. After 10 references
dispensing the controller stores all of them automatically and switches to the normal
dispensing mode. Start the dispensing cycles one after the other in order of the
requirements.
If less than 10 references dispensing are required, make your quantity of reference
dispensing. After the last required dispensing store them with button . In the display
the name of the dispensing channel changes from R to A (B) and the controller switches
to the normal dispensing mode.
All adjustments are kept stored permanently after switching off the controller.
R