Henkel KHT-900 manual Guide to Storage, Scheduled Maintenance, If Oven Fails To Operate - No Heat

Models: KHT-900

1 7
Download 7 pages 54.96 Kb
Page 5
Image 5

oven an optimum temperature. The diagonal shelf design accommodates 50 lb. electrode containers eliminating the need to remove rods from the containers. The diagonal shelf design compartments also allow air to circulate freely throughout the oven.

Guide to Storage

See the enclosed guide to storage. This guide may be used in the absence of storage information from the electrode manufacturer. In critical situations, contact your electrode manufacturer.

Scheduled Maintenance

The manufacturer recommends that unit be unloaded and cleaned of debris and dust every six months. It is also recommended that a temperature probe be placed inside the unit next to the thermocouple, and the controller calibration checked at this time.

Troubleshooting: The Keen oven model KHT-900 requires a minimal amount of electrical knowledge to repair if necessary.

IF OVEN FAILS TO OPERATE – NO HEAT

1.Check power source.

2.Check power cord continuity. Replace cord assembly if faulty.

3.Check over temperature controller’s set point and reset button.

4.Check output side of fuse block for proper voltage. If fuses are bad, inspect oven wiring and components for damage. Replace fuses.

5.Check input and output voltages on over temperature and temperature controller for proper voltage. If input voltage is not present, check wiring. If input voltage is present and there is no output voltage, replace or repair controller.

6.If output voltage is present, check for voltage at contactor coil controlled by over temperature controller. If voltage is not present, check wiring. If voltage is present at coil and contactor is in the open position, replace contactor. If the contactor is in the closed position and there is no output voltage present, replace contactor.

7.If the over temperature contactor is functioning, next check the relay operated by the temperature controller for proper control voltage and proper load voltage on the input and output sides of the relay.

8.If there is no control voltage present at the relay, check wiring to the temperature controller and temperature controller output voltage.

9.If control voltage is present at relay, check voltage between relay output and common. If no voltage is present between relay output and common, replace relay.

10.If voltage is present between relay output and common, check wiring to elements, and element continuity. Replace faulty wiring or elements.

IF OVEN FAILS TO REACH SET POINT

One or more elements may be faulty. Check continuity and replace faulty elements.

Page 5
Image 5
Henkel KHT-900 manual Guide to Storage, Scheduled Maintenance, If Oven Fails To Operate - No Heat