PROJECT
ITEM NO
Open fryers
MODEL
44 in. (1118 mm) Height includes casters
49 3/8 in. (1254 mm) | 37 3/8 in. (949 mm) |
3 electrical connections, one per well
PLAN
FRONT
Dimensions |
| Capacity |
|
|
|
|
|
|
|
| Laboratory certifications | |||||
Width | 49 3/8 in. (1254 mm) |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Vat |
| Product |
|
| Oil |
|
|
|
|
|
| |||||
Depth | 37 3/8 in. (949 mm) |
|
|
|
|
|
|
|
|
| ||||||
Per full |
| 12.5 lbs. (5.7 kg) |
| 65 lbs. (30.3 l) |
|
|
|
| ||||||||
Height | 44 in. (1118 mm) |
|
|
|
|
|
| |||||||||
Total (3) |
| 37.5 lbs. (17 kg) |
| 195 lbs. (90.9 l) |
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
| ||||||||
Required clearances | Per split |
| 6.25 lbs. (2.8 kg) |
| 25 lbs. (11.7 l) |
|
|
|
| |||||||
Sides: | 6 in. (152 mm) air flow | Total (6) |
| 37.5 lbs. (17 kg) |
| 150 lbs. (69.9 l) |
|
|
|
| ||||||
Back: | 6 in. (152 mm) air flow, connections |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Totals will vary with combinations of full and split vats |
|
|
|
| ||||||||||||
Front: | 30 in. (762 mm) filter pan removal |
|
|
|
| |||||||||||
Electrical |
|
|
|
|
|
|
|
|
|
|
|
| ||||
Crated dimensions |
|
|
|
|
|
|
|
|
|
|
|
| ||||
Length | 55 in. (1397 mm) | Well |
| Volts | Phase | Cycle/Hz | Watts |
| Amps |
| Wire |
| ||||
Depth | 39 in. (991 mm) |
| (per well) |
| (per well) |
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
| |||||
Height | 54 in. (1372 mm) |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
| 208 | 3 | 60 |
|
| 14400 |
| 39.9 |
| 3+G |
| ||||
Volume | 67.0 cu. ft. (1.90 m³) |
|
|
|
|
|
|
| ||||||||
Full |
| 240 | 3 | 60 |
|
| 14400 |
| 37.2 |
| 3+G |
| ||||
|
|
|
|
|
|
|
|
| ||||||||
Net weight | N/A | vat |
| 400 | 3 |
| 14400 |
| 20.9 |
| 3NG |
| ||||
Crated weight: | 523 lbs. (237 kg) |
|
| 480 | 3 | 60 |
|
| 14400 |
| 17.5 |
| 3+G |
| ||
Heating |
|
| Split |
| 208 | 3 | 60 |
|
| 14000 |
| 38.9 |
| 3+G |
| |
Immersed elements, maximum output: 43.2 kW |
| 240 | 3 | 60 |
|
| 14000 |
| 33.7 |
| 3+G |
| ||||
vat |
|
|
|
|
|
| ||||||||||
|
|
|
| 400 | 3 |
| 14000 |
| 20.4 |
| 3NG |
| ||||
|
|
|
|
|
|
|
|
| ||||||||
|
|
| NOTE: All watts and amps listed are per well. |
| ||||||||||||
|
|
| three electrical connections, one for each well. Power cord and plug must be |
|
| |||||||||||
|
|
| installed on site by a qualified electrician. |
|
|
|
|
|
|
Bidding Specifications
•Provide Henny Penny model
•Units can be ordered in any combination of full or split vats.
•Units shall incorporate either COMPUTRON™1000 simple digital controls or COMPUTRON™ 8000 control system (additional charge.)
•Units qualify for the ENERGY STAR® mark.
•
•Immersed fixed heating elements provide for a “cold zone” that extends oil life.
•Unit’s controller provides for programmable or manual operation with
•Units will include four
•Units can be ordered with
•Units with filtration system ship with stainless steel Max filtration screen and 2 PHT filter envelopes. All units ship with choice of 3 full baskets, 2 full and 1 half baskets, 1 full and 2 half baskets, or 6 half baskets.
Continuing product improvement may subject specifications to change without notice.
www.hennypenny.com
© 2008 Henny Penny Corporation, Eaton, OH 45320 USA 09/10/08