Adjusting the Fan Speed
A. Automatic |
|
Simply set the FAN SPEED selector to the AUTO position. |
|
A microcomputer in the air conditioner automatically controls the fan speed when the AUTO | mode is selected. When the air |
co nditioner starts operating, the difference between the room temperature (RT) and the set temperature (T) is detected by the microcomputer which then automatically switches the fan speed to the most suitable level.
Cooling mode:
When difference between room temperatureand set | FAN SPEED | |
temperature is | ||
| ||
RT ≥ T+3℃ | High | |
| ||
|
| |
T+3℃ > RT ≥ T+1℃ | Medium | |
| ||
|
| |
RT< T+1℃ | Low | |
| ||
|
| |
Mild drying mode: |
| |
When difference between room temperature | FAN SPEED | |
and set temperature is | ||
| ||
RT ≥ T+5℃ | High | |
|
| |
T+5℃> RT ≥ T+3℃ | Medium | |
|
| |
Rt≤T+3℃ | Low | |
|
| |
Heating mode: |
| |
When difference between room temperature | FAN SPEED | |
and set temperature is | ||
| ||
RT < | High | |
|
| |
Medium | ||
|
| |
Low | ||
|
|
NOTE
The above table assumes that the sensor on the remote control is being used. If the sensor in the indoor unit is
being used (the indicator is on), actual operation may differ slightly from the operation described in table.
B. Manual
If you want to adjust fan speed manually during operation, just set the FAN SPEED selector
as desired.[ (High), (Medium), or (Low)]
10