INITIAL SET SIGNALS

The following signals are used for the initial settings.

The signal timing of some computer models may be different. In such case, refer to adjust the V.POSIT and H.POSIT of the menu.

Back porch b

 

Front porch d

 

DATAHSYNC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Display interval c

 

 

 

 

 

 

 

 

 

 

 

 

Sync a

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Computer /

 

 

Horizontal signal timing (µs)

Signal

 

 

 

 

 

 

 

 

 

 

 

a

b

 

 

c

 

d

 

 

 

 

 

 

 

 

 

TEXT

 

 

2.0

3.0

 

20.3

 

1.0

 

 

 

 

 

 

 

 

 

VGA (60Hz)

 

 

3.8

1.9

 

25.4

 

0.6

 

 

 

 

 

 

 

 

 

Mac 13"mode

 

 

2.1

3.2

 

21.2

 

2.1

 

 

 

 

 

 

 

 

 

VGA (72Hz)

 

 

1.3

3.8

 

20.3

 

1.0

 

 

 

 

 

 

 

 

 

VGA (75Hz)

 

 

2.0

3.8

 

20.3

 

0.5

 

 

 

 

 

 

 

 

 

VGA (85Hz)

 

 

1.6

2.2

 

17.8

 

1.6

 

 

 

 

 

 

 

 

 

SVGA (56Hz)

 

 

2.0

3.6

 

22.2

 

0.7

 

 

 

 

 

 

 

 

 

SVGA (60Hz)

 

 

3.2

2.2

 

20.0

 

1.0

 

 

 

 

 

 

 

 

 

SVGA (72Hz)

 

 

2.4

1.3

 

16.0

 

1.1

 

 

 

 

 

 

 

 

 

SVGA (75Hz)

 

 

1.6

3.2

 

16.2

 

0.3

 

 

 

 

 

 

 

 

 

SVGA (85Hz)

 

 

1.1

2.7

 

14.2

 

0.6

 

 

 

 

 

 

 

 

 

Mac 16"mode

 

 

1.1

3.9

 

14.5

 

0.6

 

 

 

 

 

 

 

 

 

XGA (60Hz)

 

 

2.1

2.5

 

15.8

 

0.4

 

 

 

 

 

 

 

 

 

XGA (70Hz)

 

 

1.8

1.9

 

13.7

 

0.3

 

 

 

 

 

 

 

 

 

XGA (75Hz)

 

 

1.2

2.2

 

13.0

 

0.2

 

 

 

 

 

 

 

 

 

XGA (85Hz)

 

 

1.0

2.2

 

10.8

 

0.5

 

 

 

 

 

 

 

 

 

1152864 (75Hz)

 

 

1.2

2.4

 

10.7

 

0.6

 

 

 

 

 

 

 

 

 

1280960 (60Hz)

 

 

1.0

2.9

 

11.9

 

0.9

 

 

 

 

 

 

 

 

 

12801024 (60Hz)

 

 

1.0

2.3

 

11.9

 

0.4

 

 

 

 

 

 

 

 

 

12801024 (75Hz)

 

 

1.1

1.8

 

9.5

 

0.2

 

 

 

 

 

 

 

 

 

12801024 (85Hz)

 

 

1.0

1.4

 

8.1

 

0.4

 

 

 

 

 

 

 

 

 

16001200 (60Hz)

 

 

1.2

1.9

 

9.9

 

0.4

 

 

 

 

 

 

 

 

 

 

 

 

 

Back porch bFront porch d

DATAVSYNC

Display interval c

 

Sync a

Computer /

Vertical signal timimg (lines)

Signal

 

 

 

 

a

b

c

d

 

TEXT

3

42

400

1

 

 

 

 

 

VGA (60Hz)

2

33

480

10

 

 

 

 

 

Mac 13"mode

3

39

480

3

 

 

 

 

 

VGA (72Hz)

3

28

480

9

 

 

 

 

 

VGA (75Hz)

3

16

480

1

 

 

 

 

 

VGA (85Hz)

3

25

480

1

 

 

 

 

 

SVGA (56Hz)

2

22

600

1

 

 

 

 

 

SVGA (60Hz)

4

23

600

1

 

 

 

 

 

SVGA (72Hz)

6

23

600

37

 

 

 

 

 

SVGA (75Hz)

3

21

600

1

 

 

 

 

 

SVGA (85Hz)

3

27

600

1

 

 

 

 

 

Mac 16"mode

3

39

624

1

 

 

 

 

 

XGA (60Hz)

6

29

768

3

 

 

 

 

 

XGA (70Hz)

6

29

768

3

 

 

 

 

 

XGA (75Hz)

3

28

768

1

 

 

 

 

 

XGA (85Hz)

3

36

768

1

 

 

 

 

 

1152864 (75Hz)

3

32

864

1

 

 

 

 

 

1280960 (60Hz)

3

36

960

1

 

 

 

 

 

12801024 (60Hz)

3

38

1024

1

 

 

 

 

 

12801024 (75Hz)

3

37

1024

2

 

 

 

 

 

12801024 (85Hz)

3

44

1024

1

 

 

 

 

 

16001200 (60Hz)

3

46

1200

1

 

 

 

 

 

3