Maintenance chart |
|
|
|
|
|
|
|
| |
ACTION | WHY | HOW |
| |
Drain air line filter daily. | Prevent accumulation of moisture | Open manual petcock. |
| |
| and dirt. |
|
|
|
Keep lubricator filled. | Keep the Nailer lubricated. | Fill with Hitachi pneumatic tool |
| |
|
| lubricant. |
| |
Clean filter element — then blow air | Prevent clogging of filter with dirt. | Follow manufacturer’s instructions. |
| |
through filter in direction opposite to |
|
|
|
|
normal flow. |
|
|
|
|
Clean magazine and feeder | Prevent a jam. | Blow clean daily. |
| |
mechanism. |
|
|
|
|
Keep push lever working properly. | Promote operator safety and efficient | Blow clean daily. |
| |
| Nailer operation. |
|
|
|
Lubricate the Nailer after nailing. | Extend the Nailer life. | Supply 5 – 10 drops of lubricant into |
| |
|
| the Nailer. |
| |
Drain air compressor. | Keep the Nailer operated properly. | Open petcock on air compressor |
| |
|
| tank. |
| |
Operator troubleshooting |
|
|
|
|
Most minor problems can be resolved quickly and |
|
|
| |
easily using the table below. |
|
|
|
|
If problems persist, contact a Hitachi authorized |
|
|
| |
service center for assistance. |
|
|
|
|
PROBLEM | CHECK METHOD | CORRECTION |
| |
Nailer operates, but no nail is driven. | Check for a jam. | Clear a jam. |
| |
| Check function of nail feeder per | Clean and lubricate. |
| |
| page 17. |
|
|
|
| Ribbon spring weakend or damaged? | Replace ribbon spring. |
| |
| Check for proper nails. | Use only recommended nails. |
| |
Weak drive. | Check air pressure. | Increase air pressure. (Do not exceed |
| |
Slow to cycle. |
| 120 psi (8.3 bar 8.5 kgf/cm2).) |
| |
| Use Hitachi pneumatic tool lubricant. |
| ||
| Driver blade worn? | Contact Hitachi for replacement. |
| |
| Piston |
|
|
|
Drives too deep. | Check air pressure. | Reduce air pressure. |
| |
|
| (Adjust 70 – 120 psi) |
| |
Skipping nails. Intermittent feed. | Check for proper nails. | Use only recommended nails. |
| |
| Check function of nail feeder per | Clean and lubricate. |
| |
| page 17. |
|
|
|
| Ribbon spring weakend or damaged? | Replace ribbon spring. |
| |
| Use Hitachi pneumatic tool lubricant. |
| ||
| Piston | Contact Hitachi for replacement. |
| |
Nails jam. | Check for proper nails. | Use only recommended nails. |
| |
Driven nail is bent. | Driver blade worn? | Contact Hitachi for replacement. |
| |
Drives properly during normal | Check inside diameter of air hose. | Use larger air hose. |
| |
operation, but does not drive fully at |
|
|
|
|
faster nailing speeds. |
|
|
|
|
19