English
OPTIONAL ACCESSORIES | ||
○ Pneumatic Tool Lubricant | ... sold separately | |
(Code No. 877153) | ||
.8 oz. (25 cc) oil feeder | ||
4 oz. (120 cc) oil feeder | (Code No. 874042) | |
1 quart (1 ltr) can | (Code No. 876212) |
NOTE: Accessories are subject to change without any obligation on the part of HITACHI.
APPLICATIONS
○Construction wooden work such as floor and wall framing, roof decking, subflooring.
○Mobile and modular home construction.
○Making wooden boxes, palettes, and drums.
○Packing operations in manufacturing plants, and other types of packing and crating work in general.
BEFORE OPERATION
Read section titled “SAFETY” (pages 4 – 7).
Make sure of the followings before operation.
WORKING ENVIRONMENT
WARNING
●No flammable gas, liquid or other flammable objects at worksite.
●Clear the area of children or unauthorized personnel.
AIR SUPPLY
DANGER
●NEVER use oxygen or other bottled gases. Explosion may occur.
WARNING
●Never connect Nailer to pressure which potentially exceeds 200 psi (13.7 bar 14 kgf/cm2).
●Never use non relieving coupler on Nailer.
1. Power source
○ Use only clean, dry, regulated compressed air as a power source for this Nailer.
○Air compressors used to supply compressed air to this Nailer must comply with the requirements of the latest version of ANSI Standard B 19.3 “Safety Standard For Compressors For Process Industries.”
○Moisture or oil in the air compressor may accelerate wear and corrosion in the Nailer.
Drain daily.
2. | ||
○ | Use a regulator with a pressure range of 0 – 120 psi | |
| (0 – 8.3 bar | 0 – 8.5 kgf/cm2). |
○ | ||
| condition for the Nailer and extend the Nailer life. | |
| These units should always be used. | |
| Filter ............The filter removes moisture and dirt | |
|
| mixed in compressed air. |
|
| Drain daily unless fitted with an |
|
| automatic drain. |
|
| Keep the filter clean by regular |
|
| maintenance. |
| Regulator......The regulator controls the operating | |
|
| pressure for safe operation of the Nailer. |
|
| Inspect the regulator before operation to |
|
| be sure it operates properly. |
| Lubricator ....The lubricator supplies an oil mist to the | |
|
| Nailer. |
|
| Inspect the lubricator before operation |
|
| to be sure the supply of lubricant is |
|
| adequate. |
|
| Use Hitachi pneumatic tool lubricant. |
|
| Regulator |
Nailer Side | Compressor Side | |
|
| Filter |
|
| Lubricator |
3.Air hose
Air hose must have a minimum working pressure rating of 150 psi (10.4 bar 10.6 kgf/cm2) or 150% of the maximum pressure produced in the system, whichever is higher.
4.Air consumption
Using the Air consumption table and the Air compressor size formula, find a correct compressor size.
10