English

OPTIONAL ACCESSORIES

○ Pneumatic Tool Lubricant

... sold separately

(Code No. 877153)

.8 oz. (25 cc) oil feeder

4 oz. (120 cc) oil feeder

(Code No. 874042)

1 quart (1 ltr) can

(Code No. 876212)

NOTE: Accessories are subject to change without any obligation on the part of HITACHI.

APPLICATIONS

Construction wooden work such as floor and wall framing, roof decking, subflooring.

Mobile and modular home construction.

Making wooden boxes, palettes, and drums.

Packing operations in manufacturing plants, and other types of packing and crating work in general.

BEFORE OPERATION

Read section titled “SAFETY” (pages 4 – 7).

Make sure of the followings before operation.

WORKING ENVIRONMENT

WARNING

No flammable gas, liquid or other flammable objects at worksite.

Clear the area of children or unauthorized personnel.

AIR SUPPLY

DANGER

NEVER use oxygen or other bottled gases. Explosion may occur.

WARNING

Never connect Nailer to pressure which potentially exceeds 200 psi (13.7 bar 14 kgf/cm2).

Never use non relieving coupler on Nailer.

1. Power source

○ Use only clean, dry, regulated compressed air as a power source for this Nailer.

Air compressors used to supply compressed air to this Nailer must comply with the requirements of the latest version of ANSI Standard B 19.3 “Safety Standard For Compressors For Process Industries.”

Moisture or oil in the air compressor may accelerate wear and corrosion in the Nailer.

Drain daily.

2.

Filter-Regulator-Lubricator

Use a regulator with a pressure range of 0 – 120 psi

 

(0 – 8.3 bar

0 – 8.5 kgf/cm2).

Filter-regulator-lubricator units supply an optimum

 

condition for the Nailer and extend the Nailer life.

 

These units should always be used.

 

Filter ............The filter removes moisture and dirt

 

 

mixed in compressed air.

 

 

Drain daily unless fitted with an

 

 

automatic drain.

 

 

Keep the filter clean by regular

 

 

maintenance.

 

Regulator......The regulator controls the operating

 

 

pressure for safe operation of the Nailer.

 

 

Inspect the regulator before operation to

 

 

be sure it operates properly.

 

Lubricator ....The lubricator supplies an oil mist to the

 

 

Nailer.

 

 

Inspect the lubricator before operation

 

 

to be sure the supply of lubricant is

 

 

adequate.

 

 

Use Hitachi pneumatic tool lubricant.

 

 

Regulator

Nailer Side

Compressor Side

 

 

Filter

 

 

Lubricator

3.Air hose

Air hose must have a minimum working pressure rating of 150 psi (10.4 bar 10.6 kgf/cm2) or 150% of the maximum pressure produced in the system, whichever is higher.

4.Air consumption

Using the Air consumption table and the Air compressor size formula, find a correct compressor size.

10