4-8. Electrical Service Guide For 230 VAC Model

Input Voltage

230

 

 

Input Amperes At Rated Output

20

 

 

Max Recommended Standard Fuse Or Circuit Breaker Rating In Amperes

20

 

 

Min Input Conductor Size In AWG/Kcmil

14

 

 

Max Recommended Input Conductor Length In Feet (Meters)

66 (20)

 

 

Min Grounding Conductor Size In AWG/Kcmil

12

 

 

Reference: 1996 National Electrical Code (NEC)

S-0092-J

 

 

4-9. Installing Wire Spool And Adjusting Hub Tension

Installing 4 in (102 mm) Wire Spool

Installing 8 in (203 mm) Wire Spool

When a slight force is needed to turn spool, tension is set.

Adapter used with

8 in (203 mm)

spool only.

When a slight force is needed to turn spool, tension is set.

Retaining ring used with 8 in (203 mm) spool only.

Tools Needed:

1/2 in

803 012 / 803 013 -B / Ref. 802 971-C

Return To Table Of Contents

OM-944 Page 17

Page 21
Image 21