1-4. Principales normes de sé curité

Safety in Welding and Cutting, norme ANSI Z49.1, de l’American Wel- ding Society, 550 N.W. Lejeune Rd, Miami FL 33126

Safety and Health Sandards, OSHA 29 CFR 1910, du Superintendent of Documents, U.S. Government Printing Office, Washington, D.C. 20402.

Recommended Safe Practice for the Preparation for Welding and Cut- ting of Containers That Have Held Hazardous Substances, norme AWS F4.1, de l’American Welding Society, 550 N.W. Lejeune Rd, Miami FL 33126

National Electrical Code, NFPA Standard 70, de la National Fire Protec- tion Association, Batterymarch Park, Quincy, MA 02269.

Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1, de la Compressed Gas Association, 1235 Jefferson Davis Highway, Suite 501, Arlington, VA 22202.

Rè gles de sé curité en soudage, coupage et procé dé s connexes, norme CSA W117.2, de l’Association canadienne de normalisation, vente de normes, 178 Rexdale Boulevard, Rexdale (Ontario) Canada M9W 1R3.

Safe Practices For Occupation And Educational Eye And Face Protec- tion, norme ANSI Z87.1, de l’American National Standards Institute, 1430 Broadway, New York, NY 10018.

Cutting and Welding Processes, norme NFPA 51B, de la National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.

1-5. Information sur les champs é lectromagné tiques

Données sur le soudage électrique et sur les effets, pour l’organisme, des champs magnétiques basse fréquence

Le courant de soudage, pendant son passage dans les câbles de sou- dage, causera des champs électromagnétiques. Il y a eu et il y a encore un certain souci à propos de tels champs. Cependant, après avoir ex- aminé plus de 500 études qui ont été faites pendant une période de recherche de 17 ans, un comité spécial ruban bleu du National Re- search Council a conclu: “L’accumulation de preuves, suivant le jugement du comité, n’a pas démontré que l’exposition aux champs magnétiques et champs électriques à haute fréquence représente un risque à la santé humaine”. Toutefois, des études sont toujours en cours et les preuves continuent à être examinées. En attendant que les con- clusions finales de la recherche soient établies, il vous serait souhaitable de réduire votre exposition aux champs électromagnéti- ques pendant le soudage ou le coupage.

Afin de réduire les champs électromagnétiques dans l’environnement de travail, respecter les consignes suivantes :

1Garder les câbles ensembles en les torsadant ou en les attachant avec du ruban adhésif.

2Mettre tous les câbles du côté opposé de l’opérateur.

3Ne pas courber pas et ne pas entourer pas les câbles autour de votre corps.

4Garder le poste de soudage et les câbles le plus loin possible de vous.

5Relier la pince de masse le plus près possible de la zone de soudure.

Consignes relatives aux stimulateurs cardiaques :

Les personnes qui portent un stimulateur cardiaque doivent avant tout consulter leur docteur. Si vous êtes déclaré apte par votre docteur, il est alors recommandé de respecter les consignes ci–dessus.

OM-259 Page 8

Page 12
Image 12
Hobart Welding Products 302, 252TS manual Principales normes de sé curité, Information sur les champs é lectromagné tiques

302, 252TS specifications

Hobart Welding Products has established itself as a trusted name in the world of welding equipment, and among its extensive lineup, the 452,302 model stands out for its exceptional performance and versatility. This MIG welder is designed to meet the needs of both professionals and hobbyists, ensuring high-quality welds in a variety of applications.

One of the main features of the Hobart 452,302 is its robust build quality. Constructed with durable materials, this welder is designed to withstand the rigors of heavy use while maintaining consistent performance. Its compact design allows for portability, making it an excellent choice for on-site jobs or home workshops.

The 452,302 operates on a 230V input power, providing a strong output range that can handle a variety of welding tasks, from thin sheets of metal to thicker materials. It boasts a high maximum output of 230 amps, which allows it to tackle demanding projects with ease. This flexibility makes it suitable for professionals in construction, fabrication, and even automotive repair.

With its excellent arc stability, the Hobart 452,302 ensures ease of use and reduces the chance of defects in welds. The welder features an adjustable wire feed speed, allowing users to dial in the perfect setting for their specific welding task. This customization is crucial for achieving optimal results, as different materials and thicknesses require varying settings.

In terms of technology, the 452,302 integrates advanced thermal overload protection, safeguarding against overheating and prolonging the lifespan of the machine. This feature is particularly beneficial in high-demand environments, where extended periods of operation can lead to equipment failure.

The Hobart 452,302 is also compatible with a range of wire sizes and types, enabling users to expand their welding capabilities. This versatility is enhanced by the welder’s easy connectivity to gas regulators, making it suitable for both gas-shielded and flux-cored welding processes.

In conclusion, the Hobart Welding Products 452,302 is a powerful and versatile MIG welder designed to meet the diverse needs of welders. With its robust build, excellent performance features, and advanced safety technologies, it is a reliable choice for anyone seeking top-quality welding equipment. Whether you're a seasoned professional or an enthusiastic beginner, the 452,302 delivers the performance and durability necessary for successful welds on a variety of projects.