5-3. Troubleshooting

 

 

 

 

 

 

 

 

 

 

 

Trouble

 

Remedy

 

 

No weld output; unit completely inop-

Place line disconnect device in On position (see Section 3-13).

erative; pilot light PL1 off.

 

 

 

 

 

 

 

 

 

Check for open line fuse(s), and replace if open (see Section 3-13).

 

 

 

 

 

 

 

Check for proper input power connections (see Section 3-13).

 

 

 

 

 

 

 

Check for proper jumper link position (see Section 3-12).

 

 

 

 

 

 

 

Check fuse F1, and replace if necessary (see Section 5-2).

 

 

No weld output; pilot light PL1 on.

Unit overheated. Allow unit to cool with fan On (see Section 3-2).

 

 

 

 

 

 

 

If using remote control, place Output (Contactor) switch in Remote 14 position, and connect remote

 

 

 

control (see Sections 3-9 and 3-10). If remote is not being used, place switch in On position (see

 

 

 

Section 4-2).

 

 

 

 

 

 

 

Check, repair, or replace remote control.

 

 

Limited weld output and low

Check position of Remote Amperage/Voltage Control switch (see Section 4-2).

open-circuit voltage.

 

 

 

 

 

 

 

 

 

Check for open line fuse(s), and replace if open (see Section 3-13).

 

 

 

 

 

 

 

Check for proper input power connections (see Section 3-13).

 

 

 

 

 

 

 

Check for proper jumper link position (see Section 3-12).

 

 

 

 

 

 

 

Clean and tighten all weld output connections.

 

 

Unit provides only maximum or mini-

Have Factory Authorized Service Agent check control board PC1 and hall device HD1.

mum weld output.

 

 

 

 

 

 

 

 

 

Check position of Remote Amperage/Voltage Control switch (see Section 4-2).

 

 

Erratic or improper weld output.

Use proper size and type of weld cable (see Section 3-8).

 

 

 

 

 

 

 

Clean and tighten all weld connections.

 

 

 

 

 

 

 

Check wire feeder installation according to Owner’s Manual.

 

 

 

 

 

 

 

Check position of Process selector switch (see Section 4-2).

 

 

 

 

 

 

 

Have Factory Authorized Service Agent check control board PC1 and hall device HD1.

 

 

No 115 volts ac output at duplex recep-

Reset circuit breaker CB1 (see Section 3-7).

tacle, Remote 14 receptacle, or termi-

 

 

nal strip 1T.

 

 

 

 

No 24 volts ac output at Remote 14 re-

Reset circuit breaker CB2 (see Section 3-7).

ceptacle or terminal strip 1T.

 

 

 

 

Fan not operating. Note: fan only runs

Check for and remove anything blocking fan movement.

when cooling is necessary.

 

 

 

 

 

 

 

 

 

Have Factory Authorized Service Agent check fan motor.

 

 

Wandering arc; poor control of arc di-

Reduce gas flow rate.

rection.

 

 

 

 

 

 

 

 

 

Select proper size tungsten.

 

 

 

 

 

 

 

Properly prepare tungsten.

 

 

Tungsten electrode oxidizing and not

Shield weld zone from drafts.

remaining bright after conclusion of

 

 

weld.

 

 

 

 

 

 

 

 

 

Increase postflow time.

 

 

 

 

 

 

 

Check and tighten all gas fittings.

 

 

 

 

 

 

 

Properly prepare tungsten.

 

 

 

 

 

 

 

Check for water in torch, and repair torch if necessary. See torch Owner’s Manual.

 

 

Digital meter not working properly.

Have Factory Authorized Service Agent check control board PC1 and connections, and replace if

 

 

 

necessary.

 

 

 

 

 

OM-277 Page 24

Page 28
Image 28
Hobart Welding Products 302, 452 manual Troubleshooting, Trouble Remedy

302, 452 specifications

Hobart Welding Products has established itself as a trusted name in the world of welding equipment, and among its extensive lineup, the 452,302 model stands out for its exceptional performance and versatility. This MIG welder is designed to meet the needs of both professionals and hobbyists, ensuring high-quality welds in a variety of applications.

One of the main features of the Hobart 452,302 is its robust build quality. Constructed with durable materials, this welder is designed to withstand the rigors of heavy use while maintaining consistent performance. Its compact design allows for portability, making it an excellent choice for on-site jobs or home workshops.

The 452,302 operates on a 230V input power, providing a strong output range that can handle a variety of welding tasks, from thin sheets of metal to thicker materials. It boasts a high maximum output of 230 amps, which allows it to tackle demanding projects with ease. This flexibility makes it suitable for professionals in construction, fabrication, and even automotive repair.

With its excellent arc stability, the Hobart 452,302 ensures ease of use and reduces the chance of defects in welds. The welder features an adjustable wire feed speed, allowing users to dial in the perfect setting for their specific welding task. This customization is crucial for achieving optimal results, as different materials and thicknesses require varying settings.

In terms of technology, the 452,302 integrates advanced thermal overload protection, safeguarding against overheating and prolonging the lifespan of the machine. This feature is particularly beneficial in high-demand environments, where extended periods of operation can lead to equipment failure.

The Hobart 452,302 is also compatible with a range of wire sizes and types, enabling users to expand their welding capabilities. This versatility is enhanced by the welder’s easy connectivity to gas regulators, making it suitable for both gas-shielded and flux-cored welding processes.

In conclusion, the Hobart Welding Products 452,302 is a powerful and versatile MIG welder designed to meet the diverse needs of welders. With its robust build, excellent performance features, and advanced safety technologies, it is a reliable choice for anyone seeking top-quality welding equipment. Whether you're a seasoned professional or an enthusiastic beginner, the 452,302 delivers the performance and durability necessary for successful welds on a variety of projects.