OM-4418 Page 16
SECTION 5 − INSTALLATION

5-1. Installing Welding Generator

Ref install1 8/06 − Ref. 151 556 / 158 936-A / 803 467-C / S-0854
18 in
(460 mm)
18 in
(460 mm)
18 in
(460 mm) 18 in
(460 mm)
18 in
(460 mm)
Movement Airflow Clearance
Location
!Always securely fasten welding
generator onto transport vehicle
or trailer and comply with all
DOT and other applicable codes.
!Do not install unit where air
flow is restricted or engine
may overheat.
GND/PE
2
3
1
!Always ground generator
frame to vehicle frame to pre-
vent electric shock and static
electricity hazards.
1 Metal Vehicle Frame
2 Equipment Grounding
Terminal
3 Grounding Cable
Use #10 AWG or larger insulated
copper wire.
Electrically bond generator
frame to vehicle frame by met-
al-to-metal contact.
!If unit does not have GFCI
receptacles, use GFCI-
protected extension cord.
!Bed liners, shipping skids,
and some running gear insu-
late the welding generator
from the vehicle frame. Al-
ways connect a ground wire
from the generator equip-
ment grounding terminal to
bare metal on the vehicle
frame as shown.
Grounding