When using electrical appliances, basic safety precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons. These precautions include:
1.Read all instructions before using the appliance.
2.To avoid fire or shock hazard, plug the appliance directly into a 120V AC electrical outlet.
3.If the filter is covered by a bag when shipped, remove plastic bag before use.
4.Keep the cord out of heavy traffic areas. To avoid fire hazard, NEVER put the cord under rugs, near heat registers, radiators, stoves, or heaters.
5.To protect against electrical hazards, DO NOT immerse the appliance in water or other liquids. Do not use near water.
6.Close supervision is necessary when any appliance is used by or near children, or disabled persons.
7.Always unplug the air purifier before moving or cleaning the unit, opening the grill, changing the filters and whenever the unit is not in use. To disconnect the unit, be sure to pull the plug and not the cord.
8.NEVER drop or insert any objects into the openings of the unit.
9.DO NOT operate any appliance with a damaged cord or plug. If the motor fan fails to operate or the unit has been dropped or damaged in any manner, return appliance to manufacturer for examination and/or repair.
10.Use appliance only for intended household use as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock, or injury to persons. The use of attachments not recommended or sold by Jarden Consumer Solutions may cause hazards.
11.DO NOT use outdoors.
12.NEVER place on a soft surface such as a bed or sofa as this could cause the unit to tip over and block the air inlet or outlet grills.
13.Keep unit away from heated surfaces and open flames.
14.DO NOT attempt to repair or adjust any electrical or mechanical functions on this unit. Doing so will void your warranty. The inside of the unit contains no user serviceable parts. All servicing should be performed by Jarden Consumer Solutions or an authorized Jarden Consumer Solutions Center.
15.DO NOT place anything on top of unit.
16.NEVER use detergents, gasoline, glass purifier, furniture polish, paint thinner, or other household solvents to clean any part of the appliance.
17.Always turn the appliance off before unplugging it.
18.The ionizer in this appliance produces less ozone than the UL established limits of 50ppb. However, in high concentrations, ozone can be harmful to birds and small pets. To prevent ozone buildup, we suggest using the ionizer in well ventilated areas with the fan on.
19.This appliance should only be used in a room with temperatures between 40° F and 110° F.
20.WARNING: To reduce the risk of fire or electric shock, DO NOT use this appliance with any solid-state speed control device.
PLEASE READ AND SAVE
THESE IMPORTANT
SAFETY INSTRUCTIONS
CORD SAFETY
•The length of cord used on this appliance was selected to reduce tangling or tripping hazards.
•If a longer cord is necessary, an approved extension cord may be used. The electrical rating of the extension cord must be equal to or greater than the electrical rating of the air purifier (see rating label marked on product).
•Care must be taken to arrange the extension cord so that it will not drape over the countertop or tabletop where it can be pulled on by children or accidentally tripped over.
GET TO KNOW YOUR AIR PURIFIER
•Your Holmes® air purifier features a HEPA-Type filter that removes up to 99% of airborne dust and pollen as small as 2 microns, and helps reduce smoke, mold spores and pet dander from air passing through the filter.
•Arm & Hammer® baking soda and carbon help absorb and eliminate household odors.
•Optional ionizer naturally improves performance and helps freshen the air.
IONIZER
This appliance has an optional ionizer feature which, when turned on, releases negative ions into outgoing filtered air to help the air purification process.
What Are Ions?
Ions are tiny particles that carry a positive or negative charge. They exist naturally around us: in the air, water, and ground. Both positive and negative ions are colorless, odorless, and harmless.
Important Notes:
Your ionizer may produce an occasional popping or cracking sound. This is normal and occurs when a small buildup of ions is discharged.
After extended use, you may notice dust around the grills or front panel. This is caused by negative ions exiting the air outlet, evidence of the ionizer’s air cleaning effectiveness. You can remove the dust with a soft brush or clean, damp cloth.
Larger particles may be attracted to positively charged surfaces throughout the home, like walls or floors.
•This may occur more frequently when the filter is nearing the end of its useful product life and unable to capture as many charged particles.
•Excessive amounts of pet dander, dust, or smoke may decrease the life expectancy of the filter and interfere with the ionization process.
To help prevent particles from attracting to surfaces throughout your home:
•You may want to run the ionizer less often.
•Check the condition of the filter more frequently.
CAUTION: The ionizer in this appliance produces less ozone than the UL* established limits of 50ppb. However, in high concentrations, ozone can be harmful to birds and small pets. To prevent ozone buildup, we suggest using the ionizer in well ventilated areas with the air purifier fan on.
HEPA-TYPE FILTER
HEPA (High Efficiency Particulate Air) filters are designed to remove up to 99% of airborne pollutants, at 2 microns or larger, from the air that passes through them. These include tobacco smoke, household dust, pet dander and
HIGH, MEDIUM AND LOW SPEED SETTINGS
For optimum air filtration, operate your Holmes® air purifier continuously on the MEDIUM (2) setting. Its rugged motor has been designed to give many years of use. For quieter operation (such as in a bedroom), select the LOW (1) setting. When high levels of air pollution are present, select the HIGH (3) setting to quickly circulate and filter the room air.
FILTER CHECK INDICATOR
The filter indicator light eliminates guesswork by letting you know when it is time to replace the filters.
BEFORE USE
1. Carefully unpack your Air Purifier. Select a firm level place where there are no obstructions to the air inlet or filtered air outlet.
2.Remove the air inlet grill and check if the filter is covered by a plastic bag. If it is, remove plastic bag before use and place filters into unit. Reinstall the air inlet grill.
3.DO NOT POINT FILTERED AIR OUTLET TOWARDS WALL.
OPERATING INSTRUCTIONS
1. Plug into a 120V AC electrical outlet. The Filter Check Indicator light will blink three times to indicate that the feature has been activated.
2. Select the desired operating speed; HI (3), MEDIUM |
(2), LOW (1), by turning Speed Control Knob to the |
appropriate setting. For optimum air filtration, it is |
recommended to operate the air purifier |
continuously. Its rugged motor has been designed to |
F | G H I | F | G | H I |
|
| |
| | | | F |
| I | | G | |
| | H | |
| | | |
A. | Control Panel | F. | Filtered Air Outlet |
B. | Speed Control Knob | G. | HEPA-Type Filter |
C. | Filter Reset Button | H. | Washable Foam |
D. | Filter Check | | Pre-Filter | |
| Indicator Light | I. | Air Inlet Grill |
E. | Ionizer Button | | | |
CLEANING/MAINTENANCE
INSTRUCTIONS
1. Turn the air purifier off and unplug it before cleaning.
2.The outside of the air purifier can be cleaned with a soft, clean dampened cloth.
3.The air inlet grill (reference Figure 1) can be removed and washed in warm soapy water (not dishwasher safe). Dry before replacing in the unit.
4.The filtered air outlet can be cleaned of dust with a small, soft brush.
5.If you wish to clean the inside of the air purifier, please only use a dry, soft cloth to wipe it down. WARNING: Do not allow moisture to come in contact with the main housing of the air purifier.
FILTER REPLACEMENT INSTRUCTIONS
IMPORTANT:
•DO NOT attempt to wash and re-use the HEPA-type filter.
•If the filters are enclosed in plastic bags, remove
them before use.
NOTE:
Every few weeks, check the condition of filters. Filter life will vary, depending on air quality and usage. Under normal conditions of continuous use, the HEPA-type filter will operate efficiently for 3-6 months.
After approximately 4 months of operation, the Filter Check Indicator will light up to alert you to replace filters before further use.
To replace your filter:
1. Turn off and unplug the air purifier.
2.Open the air inlet grill and examine the black foam prefilter. Remove any dust or lint, and wash in warm soapy water. Rinse, drip dry, and place back into grill inlet.
3.Remove HEPA-type filter from the unit by pulling it gently towards you and discard it. DO NOT attempt to clean the old HEPA-type filter.
4.Install the new HAPF30 HEPA-type filter into the unit. This model utilizes a hang tab and filter clips to insure that the filter is properly in place. Before replacing the filter,
make sure that the hang tab is securely in place. The clip can only be attached to the tabs on the filter one way.
The filter clip should easily slide onto the filter hang tab with
only a small amount of pressure. DO NOT
use force while attaching the clip to the filter. (Fig. 2)
5. Align the clip on the side of HEPA-type filter
with rails on the inside
of the purifier unit. Gently slide the filter onto the rail. (Fig. 3)
6.Replace air inlet grill.
7.To reset the Filter Check Indicator, press and hold the button for 3 seconds. The Indicator light will blink three times and turn off.