Holmes HM2409 P L E A S E R E A D A N D S Av E T H E S E, F E At U R E S - O P E R At I O N S

Models: HM2409

1 2
Download 2 pages 44.71 Kb
Page 2
Image 2
P L E A S E R E A D A N D S AV E T H E S E

HM2409_08EM1.qxd:9100030005256 5/8/08 9:36 AM Page 2

P L E A S E R E A D A N D S AV E T H E S E

I M P O R TA N T S A F E T Y I N S T R U C T I O N S

I M P O R TA N T S A F E T Y I N S T R U C T I O N S

F E AT U R E S - O P E R AT I O N S

F E AT U R E S - O P E R AT I O N S R E P L A C I N G I N S T R U C T I O N S

C L E A N I N G / M A I N T E N A N C E S T O R A G E I N S T R U C T I O N S

When using electrical appliances, basic safety precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons, including the following:

1.

Read all instructions before using the appliance.

2.

To avoid fire or shock hazard, plug the appliance

 

directly into a 120V AC electrical outlet.

3.

Keep the cord out of heavy traffic areas. To avoid

 

fire hazard, NEVER put the cord under rugs or near

 

heat registers.

4.

DO NOT place humidifier near heat sources such as

 

stoves, radiators, and heaters. DO locate your

 

humidifier on an inside wall near an electrical outlet.

 

The humidifier should be at least 4 inches (10 cm)

 

away from the wall for best results.

5.

NEVER place humidifier in an area where it is accessible

 

to children. NEVER use humidifier in a closed room,

attachments not recommended or sold by the manufacturer may cause hazards.

11.

DO NOT use outdoors.

12.

Always place humidifier on a firm, flat, level surface.

 

A waterproof mat or pad is recommended for use

 

under the humidifier. NEVER place it on a rug or

 

carpet, or on a finished floor that may be damaged

 

by exposure to water or moisture.

13.

DO NOT allow the Moisture Outlet to directly face the

 

wall. Moisture could cause damage, particularly to

 

wall paper.

14.

Humidifier should be unplugged when not in use.

15.

NEVER tilt, move, or attempt to empty unit while it is

 

operating. Shut off and unplug before removing the

 

water tank and moving the unit.

16.

This humidifier requires daily and weekly

 

maintenance to operate appropriately. Refer to daily

22.Do not plug in the cord with wet hands: electric shock could result.

23.Do not pour water in any openings other than the water tank.

24.To prevent damage to surfaces, do not place humidifier under overhanging surfaces.

25.NEVER operate unit without water in the tank.

26.Do not move unit after it has been used , wait until unit cools completely.

27.Use both hands when carrying full tank of water.

PLEASE READ AND SAVE THESE IMPORTANT SAFETY INSTRUCTIONS

invisible moisture output. It is normal not to see the mist.

NOTE: A humidity level below 20% can be unhealthy and uncomfortable. The recommended humidity level is between 40%-50%.

PRE-OPERATING INSTRUCTIONS

1.Be sure the humidifier is switched to OFF and the unit is disconnected from the electrical outlet.

2.Select a location for your humidifier, on a flat surface, about 4 inches (10 cm) away from the wall. DO NOT place the humidifier on a finished floor or near furniture, which can be damaged by moisture or water. Place on a moisture-resistant surface.

OPERATING INSTRUCTIONS

seconds, or keep pressing the button until all the humidity indicators are OFF.

NOTE: In Manual Mode, only the LOW or HIGH power light will be lit.

1TOUCH® HUMIDISTAT INSTRUCTIONS

To take advantage of the 1Touch® Electronic Humidistat, press the MODE/OFF button until the speed is set in either the HIGH or LOW setting, and the Desired Humidity is set. When the humidity level rises above the set humidity, the humidifier will stop. When the humidity level drops below the set humidity, the humidifier will turn on automatically.

NOTE: When the 1Touch® Electronic Humidistat is set, either the HIGH or LOW power light and the percent humidity light will remain lit during operation.

A brand new filter will

Figure 2

register in the section

 

reading GOOD filter. After

 

frequent use of your

 

humidifier, the FilterCheck®

 

Indicator will let you know

 

when the filters need to be

 

changed, see Figure 2.

 

When the needle is in the

CHANGE section, this means the proper amount of moisture is not getting into your air due to the excessive minerals and sediment that have become trapped on your filters. At this point, you should replace your filter. It is important to change your filter as indicated to obtain stated performance level.

To replace the filter, follow the steps below:

CLEANING AND MAINTENANCE

INSTRUCTIONS

Humidifiers provide comfort by adding moisture to dry, heated indoor air. To benefit most from the humidifier and avoid product misuse, follow all instructions carefully. Please note that this is an electrical appliance and requires attention when in use.

In addition, if you do not follow the recommended care and maintenance guidelines, micro-organisms may be able to grow in the water within the water tank. You must routinely follow the cleaning procedures that follow in order to ensure proper, efficient operation of your humidifier. Proper maintenance and cleaning is essential to the continued performance of your unit and the avoidance of algae or bacteria build-up.

manufacturer. Leave this solution in the base for 20 minutes, while cleaning the all interior surfaces with a soft brush. Remove base scale by wiping the base with a cloth dampened with undiluted white vinegar.

3.Rinse with clean warm water to remove the cleaning solution before disinfecting the tank.

To Disinfect Humidifier Base and Tank:

1.Fill humidifier tank 1/2 full with water and 1/2 tablespoon of chlorine bleach.

2.Let the solution stand for 20 minutes, swishing every few minutes. Wet all surfaces.

3.Carefully empty the tank after 20 minutes, and rinse with warm water until you cannot detect any bleach smell. Dry with a clean cloth or paper towel.

4.Place filter back into base and refill tank as directed in Operating Instructions, and turn the unit on.

particularly where a child may be sleeping, resting, or

playing (a closed room may result in excessive

humidity).

6. WARNING: Do not attempt to refill humidifier

without first unplugging the unit from its electrical

outlet. Failure to heed this warning may cause

personal injury. Be sure to unplug the unit by pulling

on the plug and not the cord.

7. Never place anything over moisture outlet when the

unit is running.

8. NEVER drop or insert any object into any openings.

9. DO NOT operate any appliance with a damaged cord

or plug, after the appliance malfunctions, or if it has

been dropped or damaged in any manner. Return

appliance to manufacturer for examination, electrical

or mechanical adjustment, or repair.

10. Use appliance only for intended household use as

described in this manual. Any other use not

recommended by the manufacturer may cause fire,

electric shock, or injury to persons. The use of

 

and weekly cleaning procedures. Use only cleaners

 

and additives recommended by the manufacturer.

17.

NEVER use detergents, gasoline, glass cleaner,

 

furniture polish, paint thinner, or other household

 

solvents to clean any part of the humidifier.

18.

Excessive humidity in a room can cause water

 

condensation on windows and some furniture. If this

 

happens, turn the humidifier OFF.

19.

Do not use humidifier in an area where humidity

 

level is in excess of 50%. Use a hygrometer,

 

available at your local retailer or through the

 

manufacturer, to measure the humidity.

20.

DO NOT attempt to repair or adjust any electrical or

 

mechanical functions on this unit. Doing so will void

 

your warranty. The inside of the unit contains no user

 

serviceable parts. All servicing should be performed

 

by qualified personnel only.

21.

Never place housing under water flow or immerse

 

in liquids.

Consumer Safety Information

NOTE: This is an electrical appliance and requires attention when in use.

NOTE: If moisture forms on the walls or windows of the room, turn off the humidifier. The room already has plenty of humidity and additional moisture may cause damage.

NOTE: DO NOT block air inlet or outlet.

Cord and Plug Installation Safety Instructions

The length of cord used on this appliance was selected to reduce the hazards of becoming tangled in, or tripping over a longer cord. If a longer cord is necessary an approved extension cord may be used. The electrical rating of the extension cord must be equal to or greater than the rating of the humidifier (refer to the rating artwork placed on the humidifier). Care must be taken to arrange the extension cord so that it will not drape over the countertop or tabletop where it can be pulled on by children or accidentally tripped over.

Your humidifier is equipped with a technologically advanced 1Touch® Electronic Humidistat. You can set the humidifier to run continuously in manual mode or set the 1Touch® Electronic Humidistat to your desired humidity setting. The 1Touch® Electronic Humidistat will automatically turn the humidifier ON or OFF, depending on the preset comfort level. The comfort level ranges between 35% and 55% relative humidity.

Manual Mode Instructions:

1.Plug the humidifier into a 120V AC electrical outlet.

2.To start the unit, push the MODE/OFF button once for the HIGH (HI) manual setting.

3.Press the button again for the LOW (LO)manual setting.

4.To stop the unit, press and hold the button for two

Figure 1

E

F

 

 

B

NOTE: Allow up to 30 minutes for the filter to fully absorb water and for the unit to produce moisture.

NOTE: The 1Touch® Humidifier has memory. This means that when you turn the unit back on, it will be at the last setting the humidifier was set at.

If you do not plan to use the humidifier for two or more days, make sure any residual water is drained from the water tank, base and wick filter to prevent algae or bacteria growth.

EXTENDED RUN TIME SETTING

By setting your humidifier to a specific humidity level, you are actually also extending the run time. Since the unit will turn on and off to maintain the set humidity level, less water will be used, so you will need to fill the unit less than you would on manual setting.

1.Turn the unit off and disconnect from the electrical outlet.

2.Remove the tank and main housing to access the base tray.

3.Remove wick and discard.

4.Follow the weekly cleaning instructions.

5.Insert new filter.

6.Repeat Operating Instructions steps.

It will take about 30 minutes for the humidifier to reach maximum output.

You can purchase replacement filters (model HWF62) at your local retailer or by calling Consumer Service at

1-800-546-5637. It is recommended that a replacement filter is purchased for uninterrupted use.

DAILY MAINTENANCE

1.Be sure the unit is OFF and is disconnected from the electrical outlet.

2.Remove the housing and the tank from the humidifier and place in sink or tub.

3.Carry the base of the unit to the sink, remove the wick, place in sink, drain any remaining water and rinse thoroughly to remove any sediment or dirt.

Wipe clean, and dry with a clean cloth or paper towel. The base is dishwasher safe (TOP RACK ONLY) for easy cleaning.

4.Drain the water from the tank into the sink and rinse tank thoroughly. Wipe clean, and dry with a clean cloth or paper towel.

5.Put filter back in, replace the housing, then refill tank with cool tap water as instructed earlier in the Filling Instructions. Do not overfill.

6.Follow Operating Instructions.

STORAGE INSTRUCTIONS

When not using your humidifier for an extended period of time:

1.Dispose of the filters. DO NOT leave in unit.

2.Clean, rinse and thoroughly dry the humidifier as directed in weekly maintenance. DO NOT leave any water in the unit when storing. Leaving water in the unit may render the unit inoperable for the following season.

3.Place the humidifier in the original carton and store in a cool, dry place.

4.Order your replacement filter for next year’s use.

If you have any questions regarding your product or would like to learn more about other Holmes® products, please contact our Consumer Service

REPLACING THE FILTERS

Department at 1-800-546-5637 or visit our website at www.holmesproducts.com.

THIS APPLIANCE HAS A POLARIZED PLUG (one blade is wider than the other). To reduce the risk of electric shock, this plug is intended to fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician to install the proper outlet.

DO NOT ATTEMPT TO MODIFY THIS PLUG OR DEFEAT THIS

SAFETY FEATURE IN ANY WAY.

HOW COOL MIST WORKS

Your Holmes® Cool Mist humidifier draws dry air through the rear air intake grill area. This air is then passed through a moisture–laden wick filter, which retains the minerals and deposits in the water. The resulting moist air is directed back into the room from the top air grill.

NOTE: This humidification system provides a cool,

A

 

 

G

 

 

 

C

 

 

 

D

 

 

 

A.

Humidifier Tank

E.

1Touch® Button

B.

Humidifier Housing

F.

Humidity Set Lights

C.

Control Panel

G.

Speed Indicators

D.

Humidifier Base

 

(HI/LO)

Through normal use, waterborne minerals and sediment become trapped in the wick filter. The harder your water, the greater the amount of minerals in the water, and the more often you will need to change your filter.

You will be able to monitor the life of the filter in your humidifier by checking the FilterCheck® Indicator.

NOTE: After 60 minutes of use, FilterCheck® Indicator will move and indicate your filter condition.

WEEKLY MAINTENANCE

To Remove Scale:

1.Repeat steps 1-4 above.

2.Clean the base by partially filling the base with one 8-oz cups of undiluted white vinegar, or by using Cleanse Clean® solution (Model S1710) by the

Page 2
Image 2
Holmes HM2409 P L E A S E R E A D A N D S Av E T H E S E, F E At U R E S - O P E R At I O N S, Pre-Operatinginstructions