Holmes HM5082 P L E A S E R E A D A N D S Av E T H E S E, F E At U R E S - O P E R At I O N S

Models: HM5082

1 2
Download 2 pages 11.4 Kb
Page 2
Image 2
P L E A S E R E A D A N D S AV E T H E S E

HM5082-U_08EM1.qxd:9100030005027 5/5/08 3:49 PM Page 2

P L E A S E R E A D A N D S AV E T H E S E

I M P O R TA N T S A F E T Y I N S T R U C T I O N S

F E AT U R E S - O P E R AT I O N S

I M P O R TA N T S A F E T Y I N S T R U C T I O N S

F E AT U R E S - O P E R AT I O N S C L E A N I N G / M A I N T E N A N C E

W E E K LY M A I N T E N A N C E S T O R A G E I N S T R U C T I O N S

When using electrical appliances, basic safety precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons, including the following:

1.

Read all instructions before using the appliance.

2.

To avoid fire or shock hazard, plug the appliance

 

directly into a 120V AC electrical outlet.

3.

Keep the cord out of heavy traffic areas. To avoid fire

 

hazard, NEVER put the cord under rugs or near heat

 

registers.

4.

DO NOT place humidifier near heat sources such as

 

stoves, radiators, and heaters. DO locate your

 

humidifier on an inside wall near an electrical outlet.

 

The humidifier should be at least 4 inches (10 cm)

 

away from the wall for best results.

5.

NEVER place humidifier in an area where it is

 

accessible to children. NEVER use humidifier in a

 

closed room, particularly where a child may be

 

sleeping, resting, or playing (a closed room may

 

result in excessive humidity).

6.

WARNING: Do not attempt to refill humidifier

 

without first unplugging the unit from its electrical

 

outlet. Failure to heed this warning may cause

 

personal injury. Be sure to unplug the unit by pulling

 

on the plug and not the cord.

7.

Never place anything over moisture outlet when the

 

unit is running.

8.

NEVER drop or insert any object into any openings

 

unless instructed in this manual.

9.

DO NOT operate any appliance with a damaged cord

 

or plug, after the appliance malfunctions, or if it has

 

been dropped or damaged in any manner. Return

10.

Use appliance only for intended household use as

 

described in this manual. Any other use not

 

recommended by the manufacturer may cause fire,

 

electric shock, or injury to persons. The use of

 

attachments not recommended or sold by the

 

manufacturer may cause hazards.

11.

DO NOT use outdoors.

12.

Always place humidifier on a firm, flat, level surface.

 

A waterproof mat or pad is recommended for use

 

under the humidifier. NEVER place it on a rug or

 

carpet, or on a finished floor that may be damaged

 

by exposure to water or moisture.

13.

DO NOT allow the Moisture Outlet to directly face the

 

wall. Moisture could cause damage, particularly to

 

wall paper.

14.

Humidifier should be unplugged when not in use.

15.

NEVER tilt, move, or attempt to empty unit while it is

 

operating. Shut off and unplug before removing the

 

water tank and moving the unit.

16.

This humidifier requires daily and weekly

 

maintenance to operate appropriately. Refer to daily

 

and weekly cleaning procedures. Use only cleaners

 

and additives recommended by the manufacturer.

17.

NEVER use detergents, gasoline, glass cleaner,

 

furniture polish, paint thinner, or other household

 

solvents to clean any part of the humidifier.

18.

Excessive humidity in a room can cause water

 

condensation on windows and some furniture. If this

 

happens, turn the humidifier OFF.

19.

Do not use humidifier in an area where humidity

 

level is in excess of 50%. Use a hygrometer,

 

available at your local retailer or through the

20.DO NOT attempt to repair or adjust any electrical or mechanical functions on this unit. Doing so will void your warranty. The inside of the unit contains no user serviceable parts. All servicing should be performed by qualified personnel only.

21.Never place housing under water flow or immerse in liquids.

22.Do not plug in the cord with wet hands: electric shock could result.

23.Do not pour water in any openings other than the water tank.

24.To prevent damage to surfaces, do not place humidifier under overhanging surfaces.

25.NEVER operate unit without water in the tank.

26.Do not move unit after it has been used until unit cools completely.

27.Use both hands when carrying full tank of water.

PLEASE READ AND SAVE

THESE IMPORTANT

SAFETY INSTRUCTIONS

Consumer Safety Information

Note: This is an electrical appliance and requires attention when in use.

Note: If moisture forms on the walls or windows of the room, turn off the humidifier. The room already has plenty of humidity and additional moisture may cause damage.

HOW WARM MIST WORKS

Your Holmes® Warm Mist humidifier is designed to allow the proper amount of water to flow out of the tank. Air is drawn in through the grill openings located in the back of the unit and mixed with steam in the misting chamber. The warm mist is then dispersed out of the top of the misting chamber through the outlet grill and into the room.

NOTE: A humidity level below 20% can be unhealthy and uncomfortable. The recommended humidity level is between 40%-50%.

PRE-OPERATING INSTRUCTIONS

1.Be sure the humidifier is switched off.

2.Select a location for your humidifier, on a flat level surface about 4 inches (10 cm) away from the wall. DO NOT place the humidifier on a finished floor or near furniture, which can be damaged by too much moisture or water. Place on a moisture resistant surface.

3.Remove the tank from the main housing.

4.Bring the tank to the sink, turn upside down and twist off the tank cap by turning counter clockwise. Fill tank with cool, fresh tap water. DO NOT fill with warm water as this may cause leaking. Replace the cap on tank FIRMLY. The tank will hold 1.3 gallon of water. The humidifier will produce up to 2.5 gallons of water over a 24 hour time period.

5.Make sure the safety lock is rotated completely to the locked position. Place tank back on to the base. The tank will immediately begin to empty into the base.

6.Plug the humidifier into a 120V electrical outlet.

RESET PROCEDURE

NOTE: When the water tank is empty and the water in the Heating Chamber is almost empty, the Automatic Shut off will activate. The RESET Light will illuminate and the unit will not operate again until you refill the water tank and reset the humidifier.

1.Turn the power knob to RESET.

2.Unplug the unit.

3.Remove and refill the water tank, being sure to follow the Daily Maintenance Instructions. Replace the tank onto the base.

4.Wait 15 minutes for the Automatic Shut-Off to reset.

5.After the 15 minutes, plug in the unit and turn the Power Knob, to HIGH. The RESET light should now be off (if not repeat steps 1-5). In about 10 minutes, the humidifier will begin to produce moisture.

If the reset light is still on at this point, and the unit does not begin to produce moisture within a few minutes, then repeat Steps 1-5.

Figure 1

 

 

H

 

 

 

 

A

G

 

 

Low Off High

 

Reset

Low

 

Off

 

 

Reset

High

B

F

 

 

 

IMPORTANT: If you do not plan to use the humidifier for two or more days, make sure any residual water is drained from the water tank and base to prevent algae or bacteria growth.

CLEANING AND MAINTENANCE

INSTRUCTIONS

The following maintenance procedures must be routinely followed in order to ensure proper, efficient operation of your humidifier. The unit will not work properly if not cleaned regularly.

When the unit is in use, daily and weekly maintenance is recommended. Regular weekly cleaning prevents scale buildup on the heating element and tray. It also prevents micro-organisms from growing on the tray and tank. This ensures that maximum efficiency will be achieved.

We cannot over-emphasize how essential proper cleaning is to the maintenance and continued use of your unit and to the avoidance of algae or bacteria build-up.

DAILY MAINTENANCE

1.

Before cleaning, set the power knob to OFF position

 

and unplug the unit from the electrical outlet.

2.

Remove the water tank then unlock the misting

 

chamber by rotating the safety lock towards the back

 

of the unit. Lift mist chamber from the unit’s base.

 

Now lift the tray from the base.

3.

Empty water and minerals from the tray and place in

Never use detergents, gasoline, kerosene, glass cleaner, furniture polish, paint thinner or other household solvents to clean any part of the humidifier.

WEEKLY MAINTENANCE

Remove scale:

1.Repeat steps 1-3 in the Daily Maintenance section.

2.Clean the tray by partially filling the tray with one 8- oz cup of undiluted white vinegar. Let solution stand 20 minutes, cleaning all interior surfaces with a soft brush. Dampen a cloth with undiluted white vinegar and wipe out entire tray to remove scale.

3.Rinse with clean warm water to remove scale and the white vinegar solution before beginning to disinfect the tank.

4.Wipe the heating element clean with a soft cloth after it has had a chance to cool.

Disinfect tank:

1.Fill tank with 1/2 teaspoon of chlorine bleach and 1/2 gallon of water.

2.Let the solution stand for 20 minutes, swishing every few minutes. Wet all surfaces.

3.Empty the tank after 20 minutes, and rinse well with water until the bleach smell is gone. Dry with a clean cloth or paper towel.

4.Refill the water tank with cool water; replace the housing and the water tank. Repeat ALL Operating Instructions.

STORAGE INSTRUCTIONS

If your humidifier will not be in use for two days or more, or at the end of the season follow these instructions.

1.Clean, rinse and thoroughly dry the humidifier as directed in the weekly maintenance section. DO NOT leave any water inside the base or tray.

2.Wait for the heating element to cool completely, and then clean the heating element with a damp soft cloth.

3.Remove the tank cap. Do not store with the tank cap in place.

4.Place the humidifier in the original carton and store in a cool, dry place.

5.Always clean the humidifier before the next season begins.

appliance to manufacturer for examination, electrical

or mechanical adjustment, or repair.

manufacturer, to measure the humidity.

Cord and Plug Installation Safety Instructions

OPERATING INSTRUCTIONS

E

the top rack of the dishwasher. This will remove any

sediment and dirt that has accumulated in the tray.

THIS APPLIANCE HAS A POLARIZED PLUG (one blade is wider than the other). To reduce the risk of electric shock, this plug is intended to fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician to install the proper outlet.

DO NOT ATTEMPT TO MODIFY THIS PLUG OR DEFEAT THIS

SAFETY FEATURE IN ANY WAY.

The length of cord used on this appliance was selected to reduce the hazards of becoming tangled in, or tripping over a longer cord. If a longer cord is necessary an approved extension cord may be used. The electrical rating of the extension cord must be equal to or greater than the rating of the humidifier (refer to the rating artwork placed on the humidifier). Care must be taken to arrange the extension cord so that it will not drape over the countertop or tabletop where it can be pulled on by children or accidentally tripped over.

1.Fill the water tank.

2.Turn the power knob to the HIGH position. The power light will be ON and the Reset Light will be off. It is normal for the humidifier to take about 10 minutes to warm up and begin to mist.

3.After the unit begins misting, set the humidifier to the desired power setting (HIGH or LOW).

D

C

 

A. Carry Handle

 

B. Humidifier Tank

F. 2-Speed Humidity

C. Humidifier Base

Control/Power Knob

G. Humidifier Housing

D. Removable Tray

H. Vent

E. Heating Element

 

NOTE: It is imperative that the tray is cleaned properly. The tray is dishwasher safe (top rack ONLY) for easy cleaning.

4.Wipe the heating element clean with a soft cloth after it has had a chance to cool.

The Electronic Thermal Control Heating element is lined with a coating that is designed to provide the easiest cleaning and prolong the operating efficiency of the humidifier. DO NOT use any metal or hard objects to clean the Heating Element.

Page 2
Image 2
Holmes HM5082 warranty P L E A S E R E A D A N D S Av E T H E S E, F E At U R E S - O P E R At I O N S, Safety Instructions