Holmes HM729 P L E A S E R E A D A N D S Av E T H E S E, How Cool Mist Works, Daily Maintenance

Models: HM729

1 2
Download 2 pages 24.09 Kb
Page 2
Image 2
P L E A S E R E A D A N D S AV E T H E S E

HM729G-UC_08EM2.qxd:HM729G08EFM2.qxd 6/5/08 10:03 AM Page 2

P L E A S E R E A D A N D S AV E T H E S E

I M P O R TA N T S A F E T Y I N S T R U C T I O N S

P L E A S E R E A D A N D S AV E T H E S E

I M P O R TA N T S A F E T Y I N S T R U C T I O N S

F E AT U R E S - O P E R AT I O N S R E P L A C I N G I N S T R U C T I O N S

C L E A N I N G / M A I N T E N A N C E S T O R A G E I N S T R U C T I O N S

When using electrical appliances, basic safety precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons, including the following:

1.Read all instructions before using the appliance.

2.To avoid fire or shock hazard, plug the appliance directly into a 120V AC electrical outlet.

3.Keep the cord out of heavy traffic areas. To avoid fire hazard, NEVER put the cord under rugs or near heat registers.

4.DO NOT place humidifier near heat sources such as stoves, radiators, and heaters. DO locate your humidifier on an inside wall near an electrical outlet. The humidifier should be at least 4 inches (10 cm) away from the wall for best results.

5.NEVER place humidifier in an area where it is accessible to children. NEVER use humidifier in a closed room, particularly where a child may be sleeping, resting, or playing (a closed room may result in excessive humidity).

6.WARNING: Do not attempt to refill humidifier without first unplugging the unit from its electrical outlet. Failure to heed this warning may cause personal injury. Be sure to unplug the unit by pulling on the plug and not the cord.

7.Never place anything over moisture outlet when the unit is running.

8.NEVER drop or insert any object into any openings.

9.DO NOT operate any appliance with a damaged cord or plug, after the appliance malfunctions, or if it has been dropped or damaged in any manner. Return

appliance to manufacturer for examination, electrical or mechanical adjustment, or repair.

10.Use appliance only for intended household use as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock, or injury to persons. The use of attachments not recommended or sold by the manufacturer may cause hazards.

11.DO NOT use outdoors.

12.Always place humidifier on a firm, flat, level surface. A waterproof mat or pad is recommended for use under the humidifier. NEVER place it on a rug or carpet, or on a finished floor that may be damaged by exposure to water or moisture.

13.DO NOT allow the Moisture Outlet to directly face the wall. Moisture could cause damage, particularly to wall paper.

14.Humidifier should be unplugged when not in use.

15.NEVER tilt, move, or attempt to empty unit while it is operating. Shut off and unplug before removing the water tank and moving the unit.

16.This humidifier requires daily and weekly maintenance to operate appropriately. Refer to daily and weekly cleaning procedures. Use only cleaners and additives recommended by the manufacturer.

17.NEVER use detergents, gasoline, glass cleaner, furniture polish, paint thinner, or other household solvents to clean any part of the humidifier.

18.Excessive humidity in a room can cause water condensation on windows and some furniture. If this happens, turn the humidifier OFF.

19.Do not use humidifier in an area where humidity level is in excess of 50%. Use a hygrometer, available at your local retailer or through the manufacturer, to measure the humidity.

20.DO NOT attempt to repair or adjust any electrical or mechanical functions on this unit. Doing so will void your warranty. The inside of the unit contains no user serviceable parts. All servicing should be performed by qualified personnel only.

21.Never place housing under water flow or immerse in liquids.

22.Do not plug in the cord with wet hands: electric shock could result.

23.Do not pour water in any openings other than the water tank.

24.To prevent damage to surfaces, do not place humidifier under overhanging surfaces.

25.NEVER operate unit without water in the tank.

26.Do not move unit after it has been used until unit cools completely.

27.Use both hands when carrying full tank of water.

PLEASE READ AND SAVE

THESE IMPORTANT

SAFETY INSTRUCTIONS

Consumer Safety Information

NOTE: This is an electrical appliance and requires attention when in use.

NOTE: If moisture forms on the walls or windows of the room, turn off the humidifier. The room already has plenty of humidity and additional moisture may cause damage.

NOTE: DO NOT block air inlet or outlet.

Cord and Plug Installation Safety Instructions

The length of cord used on this appliance was selected to reduce the hazards of becoming tangled in, or tripping over a longer cord. If a longer cord is necessary an approved extension cord may be used. The electrical rating of the extension cord must be equal to or greater than the rating of the humidifier (refer to the rating artwork placed on the humidifier). Care must be taken to arrange the extension cord so that it will not drape over the countertop or tabletop where it can be pulled on by children or accidentally tripped over.

HOW COOL MIST WORKS

Your Holmes® Cool Mist humidifier draws dry air through the rear air intake grill area. This air is then passed through a moisture–laden wick filter, which retains the minerals and deposits in the water. The resulting moist air is directed back into the room from the top air grill.

NOTE: This humidification system provides a cool, invisible moisture output. It is normal not to see the mist.

NOTE: A humidity level below 20% can be unhealthy and uncomfortable. The recommended humidity level is between 40%-50%.

PRE-OPERATING INSTRUCTIONS

1.Be sure the humidifier is switched off.

2.Select a location for your humidifier, on a flat level surface about 4 inches (10 cm) away from the wall. DO NOT place the humidifier on a finished floor or near furniture, which can be damaged by too much moisture or water. Place on a moisture resistant surface.

OPERATING INSTRUCTIONS

1.Remove the top housing from the unit and pick up the tank.

2.Make sure the wick is in place. The rivet of the wick will be on the bottom part of the wick and attached to the holder.

3.Bring the tank to the sink and fill with water until the water level reaches the fill line making sure the wick remains in place.

4.Bring tank back to desired location and place the top housing back onto the full tank.

5.Plug the humidifier into a 120V electrical outlet.

6.To turn the unit on, switch the knob to either the High (II) or Low (I) setting. High will produce the maximum moisture and Low will produce the longest run time and quieter performance.

7.To turn the unit off, switch the knob to Off (O).

Figure 1

C

D

 

 

REPLACING THE FILTERS

Through normal use, waterborne minerals and sediment become trapped in the wick filter. The harder your water, the greater the amount of minerals in the water, and the more often you will need to change your filter.

You will be able to monitor the life of the filter in your humidifier by checking the FilterCheck® Indicator.

NOTE: After 60 minutes of use, FilterCheck® Indicator will move indicate your filter condition.

A brand new filter will

 

Figure 2

register in the section

 

reading GOOD filter. After

 

frequent use of your

 

humidifier, the FilterCheck®

 

Indicator will let you know

 

when the filters need to be

 

changed, see Figure 2.

 

When the needle is in the

CHANGE section, this means the proper amount of moisture is not getting into your air due to the excessive minerals and sediment that have become trapped on your filters. At this point, you should replace your filter. It is important to change your filter as indicated to obtain stated performance level.

To Replace the filter follow the steps below:

1.Turn the unit off and disconnect from the electrical outlet.

2.Remove the top housing to access the tank.

3.Remove the wick and discard.

4.Follow the weekly cleaning instruction.

5.Insert new filter making sure the rivet is facing the bottom of the tank and is in the rivet holder.

6.Repeat Operating Instructions.

CLEANING AND MAINTENANCE

INSTRUCTIONS

Humidifiers provide comfort by adding moisture to dry, heated indoor air. To benefit most from the humidifier and avoid product misuse, follow all instructions carefully. Please note that this is an electrical appliance and requires attention when in use.

In addition, if you do not follow the recommended care and maintenance guidelines, micro-organisms may be able to grow in the water within the water tank. You must routinely follow the cleaning procedures that follow in order to ensure proper, efficient operation of your humidifier. Proper maintenance and cleaning is essential to the continued performance of your unit and the avoidance of algae or bacteria build-up.

DAILY MAINTENANCE

1.Be sure the unit is OFF and is disconnected from the electrical outlet.

2.Remove the tank from the humidifier and place in sink or tub (this tank is also dishwasher safe TOP RACK ONLY).

3.Remove the wick, drain any remaining water and rinse thoroughly to remove any sediment or dirt. Wipe clean and dry with a clean cloth or paper towel.

4.Put filter back in the tank, then refill with cool tap water. Do not overfill.

WEEKLY MAINTENANCE

To Remove Scale:

1.

Repeat steps 1-4 above.

2.

Clean the tank by partially filling it with one 8-oz cup

 

of undiluted white vinegar or by using Cleanse Clean®

To Disinfect Tank

1.Fill humidifier tank 1/2 full with water and 1/2 tablespoon of chlorine bleach.

2.Let the solution stand for 20 minutes, swishing every few minutes. Wet all surfaces.

3.Carefully empty the tank after 20 minutes, and rinse with warm water until you can not detect any bleach smell. Dry with a clean cloth or paper towel.

4.Place filter back into tank an refill the water tank as directed in Operating Instructions, and turn the unit on.

STORAGE INSTRUCTIONS

When not using your humidifier for an extended period of time:

1.Dispose of the filters. DO NOT leave in unit.

2.Clean, rinse and thoroughly dry the humidifier as directed in weekly maintenance. DO NOT leave any water in the unit when storing. Leaving water in the unit may render the unit inoperable for the following season.

3.Place the humidifier in the original carton and store in a cool, dry place.

4.Order your replacement filter for next year’s use.

If you have any questions regarding your product or would like to learn more about other Holmes® products, please contact our Consumer Service Department at 1-800-546-5637 or visit our website at www.holmesproducts.com.

THIS APPLIANCE HAS A POLARIZED PLUG (one blade is wider than the other). To reduce the risk of electric shock, this plug is intended to fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician to install the proper outlet.

DO NOT ATTEMPT TO MODIFY THIS PLUG OR DEFEAT THIS

SAFETY FEATURE IN ANY WAY.

B PLEASE READ AND SAVE

A

A. HUMIDIFIER TANK

C. CONTROL KNOB

B. HUMIDIFIER HOUSING

D. FILTERCHECK®

 

INDICATOR

It will take about 30 minutes for the humidifier to reach maximum output.

You can purchase replacement filters (model HWF100) at a local retailer, by calling 1-800-546-5637. It is recommended that a replacement filter is purchased for uninterrupted use.

solution (model S1710) by the manufacturer. Leave

this solution in the tank for 20 minutes, while

cleaning all interior surfaces with a soft brush.

Remove the scale by wiping the tank with a cloth

dampened with undiluted white vinegar.

3. Rinse clean with warm water to remove cleaning

solution before disinfecting the tank.

Page 2
Image 2
Holmes HM729 P L E A S E R E A D A N D S Av E T H E S E, How Cool Mist Works, Pre-Operatinginstructions, Daily Maintenance