AC operation
1. Start the engine and make sure the pilot lamp comes on. If not, the fila-
ment may be burnt out.
2. Move the selector switch to the AC position.
3. Plug in the appliance.
CAUTION: Be sure that appliances do not exceed the rated load for more
than 30 minutes, and never exceed the maximum load. Substantial over-
loading will switch off the circuit breaker. Lesser overloading will not
switch off the circuit breaker and will shorten the service life of the gen-
erator.
4. Check the frequency meter to verify that the generator is operating at
60Hz. If it is not, turn the throttle knob to increase or decrease engine
speed until the correct frequency is obtained (meter bar next to 60 will
vibrate).
NOTE:
l
An overloaded AC circuit will trip the AC circuit breaker. If this occurs,
wait a few minutes before pushing the circuit breaker to resume operation.
/ FREOUENCY METER TilROTTLE KNOB