16
OPERATION
PUMP PLACEMENT
SUCTION
HEAD
DISCHARGE
HEAD
TTOOTTAALLHHEEAADD
For best pump performance, place the pump near the water level, and
use hoses that are no longer than necessary. That will enable the
pump to produce the greatest output with the least self-priming time.
As
head
(pumping height) increases, pump output decreases. The
length, type, and size of the suction and discharge hoses can also
significantly affect pump output.
Discharge head capability is always greater than suction head
capability, so it is important for suction head to be the shorter part of
total head.
Minimizing suction head (placing the pump near the water level) is
also very important for reducing self-priming time. Self-priming time
is the time it takes the pump to bring water the distance of the suction
head during initial operation.
09/02/16 10:47:01 31YG0600_017