SETTING THE KEYPAD OPTIONS
The procedures that follow are used to set the keypad address, voice chime mode, and additional voice keypad mode.
Setting The Keypad Address
When used with the
The keypad can either be set for an address of
31.For valid address settings for your keypad, refer to the control panel's Installation & Setup Guide.
Note:
•If unable to enter the address mode, power down, power up, and try again.
•If 10 seconds pass with no key entry, the keypad automatically exits the address mode. You must power down, power up, and start the address mode again.
•The keypad will not enter the address mode if the control panel is in programming mode.
1.Apply power to the keypad.
2.Within 60 seconds of applying power to the keypad, press and hold down the [1] key and [3] key at the same time for 3 seconds. The current keypad address will be displayed.
3.Press "00".
The current address is cleared.
4.Enter desired keypad address.
5.Press [*] to save the displayed address and enter the Voice Chime mode. "VOICE CHIME" (alpha keypad) or "C" (fixed keypad) is displayed along with the selected mode "1" or "0".
Setting The Voice Chime Mode
6.Press [1] to set the Voice Chime mode on or press [0] to set the Voice Chime mode off.
7.Press [*] to save the displayed Voice Chime mode and enter the Additional Console voice keypad mode.
"ADDITIONAL CON" (alpha keypad) or "A" (fixed keypad) is displayed along with the selected mode "1" or "0".
Note: Setting Voice Chime mode off does not effect the voice status or alarm annunciation.
Setting The Additional Console Mode
The Additional Console mode must be set for all voice keypads being used.
8.Set the voice keypad Additional Console mode as follows:
a.On the Primary voice keypad, press [0] to set the Additional Console mode to NO.
b.On any secondary voice keypads, press [1] to set Additional Console mode to YES.
9.Press [*] to save the mode.
VIEWING THE KEYPAD ADDRESS
Press and hold down the [1] key and [3] key at the same time for about 3 seconds. The current address is displayed. No key entry is allowed. Press any key to exit or wait 10 seconds to exit the viewing mode.
OPERATING THE KEYPAD
For operating instructions, see the User Guide for the control panel used with this keypad.
SPECIFICATIONS
2 x 16
Speaker
+12VDC
160mA (ARMED LED lit, LCD backlight and sounder on) reduces to 60mA when panel is operating in standby mode (backlight off).
190mA (ARMED LED lit, LCD backlight and sounder on) reduces to 60mA when panel is operating in standby mode (backlight off).
NFPA72 Compliant.
TABLE 1. ZONE DESCRIPTORS AND INDEX ENTRIES
ALARM | 002 | DOOR | 057 | KITCHEN | 105 | PATIO | 146 | UPSTAIRS | 207 |
ATTIC | 009 | EMERGENCY | 067 | LAUNDRY | 106 | POLICE | 151 | UTILITY | 208 |
BABY | 012 | EXIT | 071 | LIBRARY | 109 | POOL | 152 | WINDOW | 217 |
BACK | 013 | FIRE | 079 | LIVING | 113 | ROOM | 162 | YARD | 223 |
BASEMENT | 016 | FLOOR | 080 | MAIN | 122 | SHED | 168 | ZONE | 225 |
BATHROOM | 017 | FRONT | 085 | MASTER | 123 | SHOP | 170 | 1ST | 228 |
BEDROOM | 019 | GARAGE | 089 | MEDICAL | 125 | SIDE | 173 | 2ND | 230 |
CLOSED | 040 | GUN | 094 | MOTION | 131 | SLIDING | 175 | 3RD | 232 |
|
|
|
|
|
|
|
|
|
|
DEN | 050 | HALL | 095 | OFFICE | 136 | SMOKE | 176 |
|
|
DETECTOR | 052 | HOUSE | 099 | OPEN | 138 | STORAGE | 185 |
|
|
DINING | 053 | INSIDE | 101 | PANIC | 144 | SUPERVISED | 190 |
|
|
|
|
|
|
|
|
|
|
|
|
REFER TO THE INSTALLATION INSTRUCTIONS FOR THE CONTROL PANEL WITH WHICH THIS DEVICE IS USED FOR WARRANTY INFORMATION AND LIMITATIONS OF THE ENTIRE ALARM SYSTEM.
For the latest warranty information, please go to:
http://www.security.honeywell.com/hsc/resources/wa/index.html
2 Corporate Center Drive, Suite 100, P.O. Box 9040, Melville, NY 11747
Copyright 2009 Honeywell International Inc.
www.security.honeywell.com
ÊK0022V36Š
K0022V3 3/09 Rev. A