Honeywell CT3200 warranty Wire the thermostat terminals, Heating System Table

Models: CT3200

1 24
Download 24 pages 62.9 Kb
Page 7
Image 7

Heating System Table

Note: Setting the screw “out one turn” means turning the screw 360° counter-clockwise, or one complete turn.

Type of system

Screws A and B

Fuel switch

 

 

 

Warm air, gas, or oil heating system with an efficiency rating under 90%.

Use factory setting

F

(The furnace efficiency rating should be on the furnace.)

A–leave in

 

 

B–leave in

 

 

 

 

High-efficiency furnace such as a 90% or greater AFUE (Average Fuel

A–out one turn

F

Utilization Efficiency) unit

B–leave in

 

 

 

 

Hot water boiler

A–out one turn

F

 

B–leave in

 

 

 

 

Electric furnace

A–leave in

E

 

B–out one turn

 

 

 

 

Step 5. Wire the thermostat terminals

Fig. 9

G

Y

W

R

a.Hold the thermostat as shown in Fig. 9.

b.Using the labels on the wires, match the letter of your old thermostat wire with the corresponding terminal on the back of your new thermostat.

Note: If the letters on the old thermostat terminals do not match the letters on the new thermostat terminals, you might not need to connect all of the old wires to the new thermostat. See the special wiring instructions on page 9 for details.

c. Loosen the terminal screws and slip each wire beneath its

 

 

 

M20125

matching terminal (Fig 10).

Fig. 10

 

INSERT

 

d. Securely tighten the terminals.

 

 

 

 

5/16 in.

STRAIGHT

 

 

 

UNDER

 

 

 

(8 mm)

 

 

 

SCREW HEAD

 

 

 

STRIP

 

 

 

 

 

 

END OF WIRE

VISIBLE HERE

M20126

69-0653-6

INSTALLATION 7

Page 7
Image 7