M23793
Wiring CT50/CT53/CT54
• 2-wire heat-only system: Connect one
wire to R terminal, one wire to W terminal.
M23791
Wiring CT51/CT55
[1]IfwireswillbeconnectedtobothR and Rc
terminals, remove the metal jumper.
[2]DonotconnectbothO and B if you have a
heat pump. Connect only the Owire.WrapB
wire with electrical tape and do not use.
[3]DonotuseC, X or B.Wrapbareend ofwire
with electrical tape.
M23792
1. Drillholesatpencil-marked
locations(3/16”holesfor
drywall,7/32”holesfor
plaster).
2. Use hammer to tap anchors
intoholesuntilushwithwall.
3. Pullwiresthroughthermostat
base and insert screws.
Check level if desired, then
tighten screws.
Mount thermostat base1. Matcheachlabeledwirewithsame
letter on terminal.
2. Use a screwdriver to loosen screw
terminals, insert bare wires beneath
screws, then tighten screws.
3. Pushanyexcesswirebackintothe
wall opening.
Labels don't match?
If labels do not match letters on
thermostat, see table below.
Existing wires Connect to:
R• RH•4• V Terminal “R” [1]
Rc Terminal “Rc” [1]
O Terminal “O” [2]
B Terminal “B” [2]
G•F Terminal “G”
W•W1•H Terminal “W”
Y •Y1•M Terminal “Y”
C•X •B Do not use [3]
CT51/CT55
CT50/CT53/CT54
Connect wires