23 69-1532

Notice:

This thermostat is a Class B digital apparatus that complies with Canadian Radio Interference Regulations,

CRCc. 1374.

M1061
9
THERMOSTAT
1 POWER SUPPLY. PROVIDE
DISCONNECT MEANS AND OVERLOAD
PROTECTION AS REQUIRED.
11

5-WIRE HEAT/COOL

(JUMPER REMOVED)

HEATING
RELAY OR
VALVE COIL
COOLING
CONTACTOR
COIL
FAN
RELAY
B
R
RC
OWY
G
M1873
8
HEAT
RELAY COMPRESSOR
CONTACTOR
COOL
DAMPER
1POWER SUPPLY. PROVIDE
DISCONNECT MEANS AND
OVERLOAD PROTECTION
AS REQUIRED.
1

5-WIRE HEAT/COOL WITH DAMPER

(JUMPER INTACT)

B
R
RC
OWY
G
FAN
RELAY
HEAT
DAMPER
THERMOSTAT