69-1532 20
Heating does not come on. •Make sure the heating setpoint is above the room temperature.
•Make sure the circuit breaker is not tripped, and reset it if necessary.
•Make sure the power switch at the equipment is in the On position, and
set it to On if it is in the Off position.
•Wait five minutes for the system to respond.
•Set the system switch to Heat.
Cooling does not come on. •Make sure the cooling setpoint is below the room temperature.
•Make sure the circuit breaker is not tripped, and reset it if necessary.
•Make sure the system switch at the air conditioner is in the On position,
and set it to On if it is in the Off position.
•Wait five minutes for the system to respond.
•Set the system switch to Cool.
System on indicator( = heat, =
cool) is lit, but no warm or cool air is
coming from the registers.
Wait five minutes after seeing the flame or snowflake and check the
registers again. If no there is no hot or cool air coming from the registers,
refer to Heating does not come on or Cooling does not come on. If all of this
has been checked, contact your local heating and cooling contractor.
Display flashes during programming. The temperature setting limit has been reached. The heating setting range
is 40°F to 90°F (4.5°C to 32°C). The cooling setting range is 45°F to 99°F
(7°C to 37°C).
Temperature change occurs at the
wrong times.
1. Check the program times for the period in question.
2. Make sure the AM and PM settings are correct.
3. Make sure the current time and day settings are correct.
4. Reprogram any incorrect settings.
NOTE: If your thermostat is set for Smart Response™ technology, the
start times occur before your programmed comfort periods.
Thermostat backlight appears dim. •Wait until Replace Battery indicator is illuminated and replace batteries.
•Replace batteries now.
Table 4. Solution Guide.
If... Then…