7 69-0816
The subbase does not require leveling for
proper operation; level it for appearance only.
Remove thermostat from subbase (Fig. 1).
Mount the subbase directly onto the wall with
the screws included in the package. Use the
subbase as a template, and with a pencil, mark the
two mounting screw positions (Fig. 2). Use 3/16 in.
bit to drill holes for anchors. Gently tap anchors into
holes until they are flush with the wall surface.

MOUNT THERMOSTAT SUBBASE

3Thread wires through the center opening of
the subbase. Then, mount the subbase using
the two screws provided. Gently tighten the screws,
level the top surface of the subbase and then se-
curely tighten the screws.
WIRES THROUGH
WALL OPENING
WALL
WALL
ANCHORS
(2)
SUBBASE
MOUNTING
HOLES
MOUNTING
SCREWS (2)
M5175
Fig. 1—Removing thermostat from base. Fig. 2—Mounting subbase on wall.
AUX. HEAT
ONAUTO
FAN
M9073
. HT HEAT OFF COOL