Honeywell F113A, F112C, F113C manual Changing Your Filters

Models: F113C F113A F112C

1 8
Download 8 pages 50.56 Kb
Page 5
Image 5
Changing Your Filters

IMPORTANT

Replace the HEPA filter and CPZ canister every one to three years, depend- ing on the environment where the air cleaner is operating.

Table 1. Selecting Your Replacement Filters.

 

 

 

 

Air Cleaner

Prefilter

HEPA Filter

CPZ Canister

Model No.

Part No.

Part No.

Part No.

 

 

 

 

 

 

 

 

F112A6003

38002

21500

N/A

 

 

 

 

F112C6001

38002

28720

32000232

 

 

 

 

F113A6001

38002

24000

N/A

 

 

 

 

F113C6009

38002

28600

32000231

 

 

 

 

Changing Your Filters

Manual background CAUTION

Electrical Shock Hazard.

Can cause personal injury or equipment damage.

Disconnect power before servicing equipment.

NOTE: No tools are required for disassembly or assembly.

1.Disassemble the unit as follows (see Fig.1):

a.Loosen the carrying handle by turning it counterclockwise.

b.Lift the grille cover from the unit.

c.Lift the HEPA filter with carbon prefilter from the base.

d.Remove the CPZ canister, if applicable.

e.Remove the two velcro strips from the top and bottom of the prefilter and remove it from the HEPA filter.

f.Wrap the new prefilter around the HEPA filter and replace the top and bottom velcro strips.

2.Reassemble the unit as follows:

a.Place the assembled HEPA filter with carbon prefilter on the base.

b.Replace the CPZ canister, if applicable.

c.Replace the grille cover.

d.Reattach the carrying handle and turn it clockwise until securely tight. Be sure not to over-tighten.