GSC EN 50047

Safety Metal

Standard

Technical

Data

Mechanical

up to 15 million

life

operations

Degree of

IP 66

protection

NEMA/UL

 

type 1, 4, 12, 13

Temperature

Operating:

range

-25 °C to +85 °C /

 

-13 °F to +185 °F

 

Storage:

 

-40 °C to +85 °C /

 

-40 °F to +185 °F

Snap-Action Contacts

1 NORMALLY CLOSED/

1 NORMALLY OPEN

13

14

Zb

2122

Circuit closed

*Positive opening to IEC/EN 60947-5-1-3

-4,4

 

15 mm

43,3

 

(F.P.)

21-22

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(O.P.)

26˚

13-14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(R.P.)

14,5˚

FP

 

OP

* OT

 

 

 

 

21-22

 

 

 

 

DT = 9,8 mm

(D.T.)

11,5˚

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(*)

54˚

13-14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(O.T.)

61˚ to 75˚

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RP = 5,2 mm

Slow-Action Contacts

2 NORMALLY CLOSED

 

 

 

21

22

 

 

 

 

 

 

 

 

 

 

2Y

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11

12

 

 

 

 

 

-4,4

 

15 mm 36,5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

21-22

 

 

 

 

 

 

 

 

 

11-12

 

 

 

 

 

 

 

 

 

 

 

 

 

FP

 

 

OT

 

 

 

 

 

 

 

 

*

 

 

(F.P.)

 

(D.T.)

 

 

(O.P.)

26˚

(*)

 

46,5˚

(R.P.)

 

 

 

 

 

(O.T.)

61˚ to 75˚

 

 

 

 

 

 

 

 

 

 

 

 

GSS

Approvals*

IEC 60947-5-1

 

EN 60947-5-1

 

ac15 A300

 

dc13 Q300

 

BG, UL & CSA

Vibration

10 g conforming to

 

IEC 68-2-6

Shock

50 g conforming to

 

IEC 68-2-27

Terminal marking to EN 50013

21-22

13-14

21 mm

FP

DT =

 

 

0,9 mm

OP 18 mm

 

16 mm

*

15 mm

OT

 

(max.)

5,3 mm

10,5

 

21-22

13-14

18,9 mm

RP

13,9

 

 

 

21-22 11-12

FP

21 mm

 

 

 

 

 

 

18 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16,5 mm

 

 

 

 

 

 

 

 

*

15 mm

 

 

 

 

OT

 

 

 

 

 

(max.)

*See Standards (page 179)

Dimensions in mm / in

21-22

13-14

FP

 

*

OT

 

 

 

 

 

 

1,6 DT

 

 

 

 

 

 

 

 

10,5

13,5

 

 

5,3 mm

 

 

21-22

 

 

 

11-12

 

 

 

 

 

 

FP

OT

24,75 /

0.97

3 /

0.12

R 2,15 / 0.08

14,5 /

0.57

30/

1.18

22 /

0.87

20 /

0.78

 

 

 

55

/

 

2.16

30,5 /

3,5

/

1.200.138

21-22

13-14

8,9 RP

*

conduit thread

ø 23 /

ø 0.9

Note: Incorporates safety screws

Ordering:

 

 

 

 

 

 

 

* Point from which the positive opening is assured

 

 

 

19,8 /

Conduit

** Positive opening occurs at operating position. But to meet IEC/EN 60947-5-3

 

 

 

 

0.78

 

 

 

 

 

 

Thread

which requires a dielectric gap of 2,5 kV, positive opening is assured at*.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A = 1/2" NPT

C = 20 mm

 

01

Low Energy Contacts

36

Note: See page 197

GSC

 

X

 

XX

 

 

Example: GSC C 01 B

 

 

202

Industrial Safety Products

GSS Series

Page 6
Image 6
Honeywell GSS Series manual Gsc En, Normally Closed Normally Open