HCD544/HCD544X/HCD545X Camera Quick Install Guide

Document 800-03503 — Rev C — 03/09

Important Safety Instructions

Read and keep these instructions.

Heed all warnings.

Follow all instructions.

Do not use this apparatus near water.

Clean only with dry cloth.

Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.

Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.

Use only with the bracket or mounting system specified by the manufacturer, or sold with the apparatus.

Refer all servicing to qualified service personnel.

Installation

Adjusting the Back Focus

To adjust the back focus, aim the camera towards a darker area, or use a Neutral Density lens filter. For best results, there should be a minimum of 15 ft (4.5 m) between the camera and the target focal area.

1.Loosen the setscrews (see Figure 1) with a Phillips screwdriver.

2.Set the Zoom lens adjustment to Wide and the Focus lens adjustment to Near.

3.Adjust the back focus ring to focus the picture.

4.Retighten the setscrews.

Mounting the Camera

There are mounting points on the top and bottom of the camera (see Figure 3) to mount the camera on a bracket or tripod. Use standard sized mounting bolts to install the camera to a mounting bracket.

Caution Follow local installation codes for proper mounting bracket support capability.

Figure 3 Camera Mounting.

Top view shown

The HCD544 Series camera is designed for general surveillance applications and is ideally suited for low-light indoor environments.

Installing the Lens

The HCD544 Series camera is factory configured for a CS-mount lens. Screw the lens (customer supplied) into the front of the camera body. An IR corrected Day/Night lens is recommended for this camera.

Figure 1 Lens Installation

DC Lens Pin Definitions

Setscrews (x2)

Pin

Function

 

 

 

 

 

 

 

 

 

 

 

1

CTRL -

3

4

 

 

 

 

2

CTRL +

 

1

2

 

 

 

 

3

DRV +

 

 

 

 

 

 

 

 

 

4

DRV -

 

 

 

 

 

 

 

Connecting the Camera

Note Check the power source from the external power supply before applying power to the camera.

1.Connect the VIDEO connector on the rear of the camera to the video-in connector on your monitor or video recorder.

2.HCD544/HCD544X models: Connect the camera to a power supply appropriate for your installation (12 VDC or 24 VAC).

Plug the power supply into an appropriate power source.

3.HCD545X model: Connect the power cord to the power cord socket.

Plug the power cord plug into an electrical outlet of AC230V, 50 Hz. Accepted voltage range is 207 VAC~253 VAC.

The power LED illuminates to show that the camera is receiving power.

Figure 2 Video Connections

HCD544/HCD544X

Power LED

LAMP terminal

GND terminal

AC24V/DC12V terminal block

Mounting point

Making Final Adjustments

Adjust the focus in your field of view until you see a clear image. If necessary, adjust the brightness using the OSD menu controls (see LENS DC/BRIGHTNESS or AGC). Confirm the exposure on the monitor screen.

Programming

OSD Menu Controls

Figure 4 Camera Controller

Camera OSD control Navigating through the menus

(4 position plus center press (ENTER)

Press this control To do this …

ENTER

Press and hold two seconds to enter

 

SETUP menu. Press to enter a

 

screen or select a menu option.

 

 

UP, DOWN

Move vertically between menus and

(!, ")

options. Increase/decrease a value.

 

 

LEFT, RIGHT

Move horizontally between menus

(#, $)

and options.

 

 

..

Indicates submenus. Select the

 

menu, then press ENTER.

 

 

RETURN (on OSD

Exit the submenu. Select RETURN,

submenus)

then press ENTER.

Note Menu display turns off automatically after five minutes of no activity. Your changes will be saved.

OSD Menu Structure

The HCD544 Series camera menu system consists of one main SETUP menu for easy camera programming.

Figure 5

Menu Structure

 

Main Menu

Submenu

Menu Options

 

LENS

DC .., MANUAL

HCD545X

Power LED

SHUTTER

 

FLK, MANUAL .., ESC

 

GND terminal

230 VAC power supply

1

<<SETUP MENU>>

LENS

DC

2

SHUTTER

MANUAL ..

3

WHITE BAL.

AWC ..

4

BACKLIGHT

ON

WHITE BAL

 

ATW ..

, AWC (PUSH/LOCK), AWC

 

 

 

AUTO

..,USER .., MANUAL ..

LAMP terminal

Connecting LAMP Contact

The HCD544 camera is equipped with LAMP and GND external contact terminals (see Figure 2). When the LAMP terminal is connected to the GND terminal, the camera is forced into night mode (see DAY&NIGHT). It stays in night mode until the LAMP terminal is disconnected from the GND terminal.

5 AGC

30dB

6SPECIAL ..

7EXIT MENU ..

See SETUP Menu Functions for a description of the submenus and menu options.

BACKLIGHT

ON, OFF

AGC

18 dB~30 dB, OFF

SPECIAL ..

See SPECIAL Menu.

Document 800-03503 – Rev C – 03/09

Page 1
Image 1
Honeywell HCD544X important safety instructions Adjusting the Back Focus, Mounting the Camera, Installing the Lens

HCD545X, HCD544, HCD544X specifications

The Honeywell HCD544, HCD544X, and HCD545X are advanced heating and cooling devices designed to meet the demands of both residential and commercial applications. These models harness cutting-edge technology to deliver exceptional performance, reliability, and energy efficiency.

The HCD544 is known for its unique heating capabilities, combining both convection and radiant heating for a balanced thermal distribution throughout the space. This model is equipped with a precise digital thermostat that allows users to set their desired temperature with accuracy. The energy-saving mode ensures that energy consumption is minimized while maintaining comfort, making it an environmentally friendly choice.

The HCD544X, an upgraded version of the HCD544, incorporates additional features such as enhanced Wi-Fi connectivity. This allows users to control their heating and cooling systems remotely through their smartphones or other smart devices. The model is compatible with various home automation systems, facilitating seamless integration into modern smart homes. Additionally, the HCD544X includes an advanced air purification system, providing improved indoor air quality by filtering out allergens, dust, and other pollutants.

In contrast, the HCD545X takes innovation up a notch by introducing an inverter-driven compressor that adjusts its speed based on the current heating or cooling demand. This feature not only improves overall energy efficiency but also enhances comfort by reducing temperature fluctuations. Furthermore, the HCD545X boasts a robust construction with a weather-resistant design, making it suitable for outdoor installations in various climates.

All three models utilize Honeywell's patented dual-zone technology, allowing users to create distinct temperature zones within their environments. This capability offers tailored comfort and increases energy efficiency by ensuring that energy is not wasted in unoccupied spaces.

In summary, the Honeywell HCD544, HCD544X, and HCD545X represent a line of innovative heating and cooling solutions that prioritize comfort, efficiency, and modern conveniences. With features ranging from precise digital controls to air purification and smart home compatibility, these devices are a testament to Honeywell's commitment to providing high-quality, user-friendly climate control solutions for a diverse range of applications. Whether for residential or commercial use, these models deliver reliability and performance in any setting.