56
Installing UltraKey Lite with MAXPRO-Net
Baud Rate: 19.2 KB
Data Bit: 7
Parity: Even
Stop Bit: 1
Installing and Configuring an Ethernet ConnectionStep 1: Connect to the UltraKey Lite Ethernet Port
1. Plug an RJ45 network cable from the network to the controller Ethernet port. Up to 99
controllers can be connected to the network. See Figure 4-11.
2. Connect MAXPRO-Net to the network. Refer to the applicable MAXPRO-Net
Installation Guide for instructions.
Figure 4-11 Ethernet Port Connections to MAXPRO-Net
Table 4-3 RJ45 Ethernet Pin Assignments
Port Pin Signal
RJ45
Ethernet
1TX +
2TX –
3RX+
6RX –
Ethernet Port
RJ45 Network cables
Ethernet Port
Controller 1
Controller 32
TCP/IP
TCP/IP
Network
MAXPRO-Net TCP/IP