HONEYWELL SECURITY TECHNICAL BULLETIN | 11 December 2008 |
|
|
Honeywell Video Systems
Subject: Control
Introduction
This document describes the Protocol Interface Translator (PIT) operation specific to the Honeywell
Quick Start Switch Settings
Output | S1/8 |
| S1/7 |
| S1/6 |
| S1/5 |
| S1/4 | S1/3 | S1/2 | S1/1 |
Protocol |
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
| Valid |
| Valid |
| Valid |
| Valid |
| ASCII | ASCII | ASCII | ASCII |
|
|
|
|
| string | string | string | string | ||||
| Function |
| Function |
| Function |
| Function |
| ||||
|
|
|
|
| mode | mode | mode | mode | ||||
|
|
|
|
|
|
|
|
| ||||
| Off |
| Off |
| Off |
| Off |
| On | On | On | On |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Address | S2/8 |
| S2/7 |
| S2/6 |
| S2/5 |
| S2/4 | S2/3 | S2/2 | S2/1 |
|
|
|
|
|
|
|
|
|
|
|
|
|
Switch | Address |
| Address |
| Address |
| Address |
| Address | Address | Address | Address |
Legend | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 | ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
0 (B/cast) | Off |
| Off |
| Off |
| Off |
| Off | Off | Off | Off |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Input | S3/8 |
| S3/7 |
| S3/6 |
| S3/5 |
| S3/4 | S3/3 | S3/2 | S3/1 |
Protocol |
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
| Slave Port |
| Slave |
| Master |
| Master |
| Input | Input | Input | Input |
|
| Port |
|
|
| |||||||
| Baud |
|
| Port Baud |
| Port Baud |
| Type | Type | Type | Type | |
|
| Baud |
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
| |
Bossware | On |
| Off |
| On |
| Off |
| On | On | On | Off |
|
|
|
|
|
|
|
|
|
|
|
|
|
The above setting set the PIT as follows:
Receive Betatech compatible Bossware control messages on the RS422 slave port of the PIT at 19.2K baud. The PIT unit address (S2/1 - S2/8 to OFF position) is set to broadcast, so all addresses will be translated. If want to control specific unit of DVR, set the dip switch S2/1 – S2/8 of PIT address and add PIT per DVR. (It is tested the address from 1 to 128.)
| Unit ID | S2/8 | S2/7 |
| S2/6 | S2/5 | S2/4 |
| S2/3 |
| S2/2 | S2/1 |
|
| 1 | Off | Off |
| Off | Off | Off |
| Off |
| Off | On |
|
| 2 | Off | Off |
| Off | Off | Off |
| Off |
| On | Off |
|
| 3 | Off | Off |
| Off | Off | Off |
| Off |
| On | On |
|
| 4 | Off | Off |
| Off | Off | Off |
| On |
| Off | Off |
|
| 5 | Off | Off |
| Off | Off | Off |
| On |
| Off | On |
|
| : |
|
|
|
|
|
|
|
|
|
|
|
|
| 255 | On | On |
| On | On | On |
| On |
| On | On |
|
| Transmit | Honeywell |
|
| |||||||||
| Note: To control |
|
|
|
| ||||||||
| (Tested firmware: HVBCPUX – 4.96x | HVBCFG – 3.08 (Build 32) | HVBPIT44 – 3.03) |
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| www.asia.security.honeywell.com |
|
|
|
|
| Rev 1.0 | 1 of 5 |
|