Installation Guide
69-2198—01 4
The DS/BK terminal is used with a variable-speed fan.
Connect the DS, BK, ODD, or DHUM terminal on the
HVAC equipment to this terminal. When 1 zone is calling
(or 25% on systems with more than 4 zones) this termi-
nal will be de-energized of 24 VAC. This reduces blower
speed on most variable speed blowers.
Connect DATS as shown.
5Connect equipment as shown.
7C7735A1000 M24804
DATS
DATS
SENSOR
9Connect transformer as shown.
DEDICATED
TRANSFORMER
R
C
M24806
R
C
POWER
L1
(HOT)
L2
RH
RC
W1/E
W2
W3
Y1
Y2
G
O
B
DS/BK
M24809
HVAC
FAN RELAY
24 VOLT TRANS.
G
Y
Y2
CR
W
COMPRESSOR
RELAY
W2
EQUIPMENT
WiriNg
Fig. 7
Fig. 9
Fig. 11
8If using any wireless devic e, connect
the ABCD terminals for th e wireless
interface module.
M28193
A
B
C
D
WIRELESS
ADAPTER
WIRELESS
CONNECT
POWER
THM4000R
CONNECTED
WIRELESS SETUP
Fig. 10
Connect outdoor air temper ature sensor
as shown. Required for dua l fuel systems;
optional for other multistag e systems.
6Fig. 8
M28207
OT
OT
SENSORS
C7089U1006
OUTDOOR
TEMPERATURE
SENSOR