KNI 582

SPECIFICATION

CHARACTERISTIC

 

 

 

 

POWER REQUIREMENTS

 

Primary:

11.33VDC 0.4A maximum

 

26VAC 400Hz 6VA

Lighting:

28V at 80mA maximum

 

5V at 460mA maximum

 

Note: 14V Installations may use 5V Versions

 

with dropping resistor.

 

 

COMPASS HEADING INPUT

Operates from any slaved magnetic compass

 

with ARINC X, Y, and Z outputs. Z grounded

 

externally.

 

 

COMPASS VALID

Valid = +27.5VDC

 

Invalid = 0VDC 2mA maximum

 

 

VOR/LOC COMPOSITE INPUT

0.5VRMS 0° phase composite 30Hz variable AM

(-04 Version TACAN

and 30Hz reference FM on a 9960Hz carrier

Compatible)

(ARINC Std.) (0.7VRMS maximum)

 

 

NAV SUPERFLAG

Flag < +3.5VDC

(Horizontally parked needle)

No Flag > +10VDC

 

 

ILS ENERGIZE

ILS < +1VDC (GND)

(Horizontally parked needle)

VOR = Open (+33VDC Maximum)

 

 

ADF X, Y, Z

Operates from any ADF receiver with ARINC X,

 

Y, Z outputs. Z grounded externally. 11.8VRMS

 

400Hz 180° index, positive rotation reference.

 

 

OBI SIN/COS

4 wire SIN/COS 10VRMS 400Hz. 0° when SIN =

 

0VRMS and COS = maximum positive VRMS.

 

Positive rotation reference with COS decreasing

 

and SIN increasing in-phase for increasing

 

degrees.

 

 

ADF DC SIN/COS

Common Mode: 0 to ± 5VDC

 

Differential: 3VDC ± 10%

 

 

OBI DIGITAL

 

I Electrical Characteristics

 

A. Driver

1. Open collector referenced to ground

 

2. Maximum “low” voltage (with 2 receiver loads

 

(500 Ohm) returned to 10.35 volts) = 1.0V.

 

 

Table 1-1 - KNI 582 RMI Technical Characteristics (Cont)

Rev 3, March/2007

©Honeywell International Inc. Do not print without express permission of Honeywell.

1-2

Page 14
Image 14
Honeywell KNI 582 Specification Characteristic Power Requirements, Compass Heading Input, Compass Valid, NAV Superflag

KNI 582 specifications

The Honeywell KNI 582 is a state-of-the-art gas detector designed for industrial and commercial applications. This device is engineered to ensure the safety of environments where hazardous gases may be present. It is recognized for its robust construction and advanced features that provide reliable detection, making it an essential tool for maintaining safe operating conditions.

One of the standout characteristics of the Honeywell KNI 582 is its capability to detect multiple gases simultaneously. Equipped with advanced sensors, the KNI 582 can monitor for gases like methane, propane, and carbon monoxide. This multi-gas detection feature enhances safety by providing real-time awareness of potential hazards.

The KNI 582 employs Honeywell's patented sensor technology, which boasts high sensitivity and rapid response times. This technology allows the device to detect gas leaks swiftly, minimizing the potential for dangerous situations. Additionally, its intelligent calibration system ensures accuracy over time, requiring less frequent manual calibration and reducing maintenance burdens.

The design of the Honeywell KNI 582 integrates a user-friendly interface, featuring an easy-to-read display that shows gas concentrations and operational status. Alarm notifications, both visual and audible, alert users to unsafe conditions, allowing for immediate action. This feature is crucial in environments where minutes can make a difference in emergency situations.

Durability is another key aspect of the KNI 582. Constructed with high-quality materials, it is designed to withstand harsh industrial conditions, including exposure to dust, moisture, and temperature variations. Its robust housing ensures longevity and reliable performance in challenging environments, making it a cost-effective investment over time.

In terms of connectivity, the KNI 582 can interface with various monitoring systems and safety devices. This compatibility allows for integration into broader safety protocols, enhancing situational awareness and operational safety. The ability to connect to external systems for remote monitoring and data logging adds further value, enabling organizations to track gas levels over time and respond proactively to potential threats.

Overall, the Honeywell KNI 582 stands out in the field of gas detection with its advanced technologies, reliability, and user-centric design. Its multi-gas detection capabilities, rapid response time, and integration options make it an indispensable component of modern safety management systems, ensuring personnel and facility safety in potentially hazardous environments.