USE & OPERATION

Touch Screen Control Panel

 

Warning Light

 

(when flashing)

 

 

 

STOP

 

Timer Control

 

Power Control

Fan Speed Control

Timer / Temperature Set Controls

Mode Control

 

 

 

Power Control

The Power Control turns the unit on and off.

Mode Control

3 settings: Cool, Dehumidify and Fan

A light will indicate which setting is currently being used.

• Cooling Mode

The unit works as an air conditioner. Adjust fan speed and air temperature to suit your desired comfort level. Temperature setting range is 61°F~89°F.

• Dehumidifying Mode

Air is dehumidified as it passes through the unit, without being in full cooling mode. If room temperature is higher than 77°F

fan speed can be adjusted; otherwise fan speed is preset "LOW".

Note : If the unit will be used mainly as a dehumidifier, do not connect the exhaust hose and let the warm air return in the room. Continuous drainage is then necessary and more efficient (refer page 14, Continuous Draining).

• Fan Mode

For air circulation without cooling.

• Heating Mode

When heating mode is selected the indicator light will shine. Heating is activated only when the ambient temperature is below 25°C . In this mode, the desired temperature can be set between 16°C and 25°C.

Note: The air exchange hoses must vent outside the room when using heating mode.

Note: unit does not need to be vented in Fan mode.

Fan Speed Control

3 settings: High, Medium and Low.

Timer Control

Auto turn off:

With machine in running mode, press timer button to select the number of hours you want the unit to run in air conditioning mode.

Auto turn on:

With machine in stand by mode, press the timer button to select the number of hours until you want the unit to automatically start running.

Temperature / Timer Set Controls

Used for adjusting the timer and thermostat.

The default display is room temperature.

In cooling mode, when “ “ or ““ button is pressed, the set temperature is displayed and may be adjusted.

After 10 seconds the display will revert back to room temperature. Temperature is only adjustable in cool mode.

The time is adjustable between 1~24 hours.

Note : By pressing both “ “ / ““ set buttons at the same time, the display will toggle between Celsius and Fahrenheit.

Warning Light

Condensed water may accumulate in the unit. If the internal tank becomes full, the Power Light will flash and the unit will not operate until the unit has been drained (refer page 14, Water Condensation Drainage).

After switching the air conditioner off, you must wait 3 minutes before switching it back on again.

10

Page 11
Image 11
Honeywell MM14CHCS owner manual USE & Operation, Touch Screen Control Panel

MM14CHCS specifications

The Honeywell MM14CHCS is a versatile and powerful portable air conditioner designed to provide effective cooling in a variety of environments, from homes to offices. This unit boasts a 14,000 BTU cooling capacity, making it ideal for spaces of up to 550 square feet, ensuring that users can enjoy a comfortable atmosphere even during the hottest months.

One of the standout features of the Honeywell MM14CHCS is its ability to operate in multiple modes. It offers cooling, dehumidifying, and fan modes, allowing users to tailor their comfort level based on current conditions. The dehumidification function operates independently and can remove up to 70 pints of moisture from the air per day, which helps improve indoor air quality and prevent mold growth.

This portable air conditioner utilizes a dual hose design that enhances efficiency. The two hoses work in tandem—one draws in outside air for cooling, while the other expels hot air, resulting in faster cooling times and reduced energy consumption. This design mitigates the negative pressure often associated with single-hose portable units, making the MM14CHCS a more effective option for regulating indoor temperatures.

The MM14CHCS is equipped with a user-friendly control panel and a digital display for easy operation. Additionally, it comes with a remote control, providing added convenience for adjusting settings from a distance. The unit includes a 24-hour programmable timer, which allows users to set specific cooling schedules, thus optimizing energy use and increasing convenience.

Portability is another key characteristic of the Honeywell MM14CHCS. With built-in caster wheels and side handles, moving the unit from one room to another is seamless. It also features an easy-to-install window venting kit, which allows for a hassle-free setup in various window types.

In terms of energy efficiency, the MM14CHCS is designed with an eco-friendly refrigerant and boasts a high Energy Efficiency Ratio (EER), contributing to lower energy costs. The quiet operation of the unit ensures that it does not disrupt daily activities or sleep, making it suitable for bedrooms and workplaces alike.

Overall, the Honeywell MM14CHCS is a reliable and efficient solution for those seeking portable cooling. Its advanced features, combined with its user-friendly design, make it a strong choice for consumers looking to enhance their indoor comfort while maintaining energy efficiency.